Troubleshooting Chart
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
7) Attach supply lines to shut-off
valves and hand tighten. Using a
wrench, nish with one-half turn.
DO NOT overtighten.
Maintenance
1) Turn off water supply. Remove
plug button (A). Loosen and
remove the handle set screw (B),
handle (C), collar (D) and nut (E).
7
6
4
3
2
1
5
E
A
B
C
D
2) Remove old cartridge. Correctly
align new cartridge (G) and insert
into faucet body (H). Install nut (E)
and secure collar (D).
3
4
2
H
D
E
G
3) Replace handle (C) and reinstall
set screw (B). Tighten set screw.
Reinstall plug button (A).
8) Remove aerator (I) and ush lines
free of debris. Check for leaks.
1
1
2
9) Adjust limit stop washer to limit
handle turn to the hot position if
desirable.
2
Installation
I
1
1
4
2
3
C
A
B
Note: Counterclockwise to lower
temperature, clockwise to increase
temperature.