Installation Guide

Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2015 Symmons Industries, Inc. www.symmons.com gethelp@symmons.com ZV-3116 REV A 080515
Troubleshooting Chart
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
7) Attach supply lines to 1/2” IPS inlet
connections on faucet body (H).
Using a wrench, nish with one half
turn. DO NOT overtighten.
Maintenance
1) Remove set screw (A). Turning
counterclockwise, disassemble
handle (C) and nut (D) from car-
tridge (E or F).
C
A
D
E
F
2) Remove cartridge (E or F) from
faucet body (H). Inspect for
debris.
Replace cartridge if
necessary.
E
F
H
3) Install cartridge and handle assembly
following steps 1 and 2 in reverse.
H
8) Attach supply lines to shut-off
valves and hand tighten. Using a
wrench, nish with one-half turn.
DO NOT overtighten.
1
1
2
9) Remove aerator (G) and ush
lines free of debris. Check for
leaks.
1
2
G
Installation