Installation Guide
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2016 Symmons Industries, Inc. ■ symmons.com ■ gethelp@symmons.com ■ ZV-3205 REV 0 ■ 050216
Installation
7) Attach supply lines to IPS inlet
connections (I). Using a wrench,
nish with one half turn. DO NOT
overtighten.
I
1
1
2
8) Attach supply lines to shut-off valves
and hand tighten. Using a wrench,
nish with one-half turn. DO NOT
overtighten.
1
1
2
9) Turn on water supplies. Remove
aerator (H) and ush lines free of
debris. Check for leaks.
2
1
H
Maintenance
1) Turn off water supply. Loosen and
remove the handle set screw (B),
handle (A), collar (C) and nut (D).
A
C
D
2
3
4
B
1
2) Remove cartridge (F, G) and inspect
for debris. Replace cartridge if
necessary.
3) Install cartridge following steps
1 & 2 in reverse.
F
G
Problem Cause Solution
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Troubleshooting Chart