7) Attach supply lines (M) to shut-off
valves and hand tighten. Using a
wrench, nish with one-half turn.
DO NOT overtighten.
1
1
M
2
8) Remove ow restrictor (J) and ush
supply lines free of debris. Check
for leaks.
2
2
J
9) Optional: Adjust limit stop washer
to limit handle turn to the hot
position if desirable.
Note: Counterclockwise to lower
temperature, clockwise to increase
temperature.
1
3
2
+
_
Maintenance
1) Turn off water supply. Remove plug
button (B). Loosen and remove the
handle set screw (C), handle (A),
collar (D) and nut (E).
4
3
1
2
5
A
B
C
D
E
2) Remove cartridge (H) and inspect
for debris. Replace cartridge if
necessary.
3) Install cartridge following steps
1 & 2 in reverse.
H
Problem Cause Solution
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Troubleshooting Chart