Installation Sheet

Installation
8) Insert pivot rod (T) into drain
body (Q) against gasket (P) and
inner seat (R). Install outer seat
(S) against pivot ball and secure
assembly by tightening retaining
nut (U).
Note: Pivot rod passes under
stopper.
9) Insert lift rod (J) into back of
faucet body (E). From below,
attach clevis strap (W) to lift
rod (J). Tighten thumb screw to
secure.
10) With stopper in closed location,
insert pivot rod (T) into clevis
strap (W). Secure with spring
clip (V).
11) To adjust stopper, select
another hole in clevis strap or
loosen thumb screw to slightly
raise or lower lift rod.
12) Attach drain body to drain trap.
1
T
S
U
Q
R
P
2
2
1
3
J
E
J
W
T
W
V
V
Troubleshooting Chart
Problem Cause Solution
Finish is spotting. Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then
quickly rinse with water.
Faucet is leaking from handle
or faucet body.
Cartridge o-rings are worn or foreign
matter (dirt, chips) is lodged between
cartridge and o-rings.
Remove cartridge and inspect for
foreign matter. Replace cartridge
if necessary.
Faucet no longer maintains desired
temperature.
Hard water deposits inside of
cartridge is preventing accurate mix
of hot and cold water.
Soak cartridge in white vinegar for
1 hour to breakdown hard water
deposits, then rinse with water.
Replace cartridge if necessary.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2020 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3030 REV I 011320
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to
cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.