Installation Guide

Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2015 Symmons Industries, Inc. www.symmons.com gethelp@symmons.com ZV-3115 REV A 112515
Troubleshooting Chart
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
9) Connect lift rod (A) to clevis strap
(S2) and secure with thumb screw
(S3). Insert pivot rod (S13) into
clevis strap (S2). Secure with
spring clip (S8) and adjust linkage
if necessary.
1
3
4
4
A
S8
S13
S2
2
S3
S2
10) Connect hoses (T) and supply
lines. Remove aerator (J) with
removal key (K) and ush lines
free of debris. Check for leaks.
4
1
1
1
J
K
T
Maintenance
1) Remove set screw (B). Turning
counter-clockwise, disassem-
ble handle (C) and nut (G) from
cartridge (H or I).
B
C
G
H
I
8) Attach sealing washer (S12), pivot
rod (S13) and cup washer (S14)
to tailpiece (S11). Hand tighten
nut (S7) clockwise to secure pivot
rod (S13).
S13
S11
1
S12
S14
S7
2
2) Remove cartridge (H or I) from
valve body (M). Inspect for debris.
Replace cartridge if neccessary.
M
H
I
3) Install cartridge and handle assembly
following steps 1 and 2 in reverse.
3
2
3
Note: Apply plumber tape to inlet
of shut off valves.
Installation