Installation Sheet

Tools & Materials
 Need Help?
Contact Symmons customer service
Phone: (800) 796-6667
gethelp@symmons.com
Mon - Fri 7:30 am - 6:00 pm EST
Please check Symmons website
for technical help.
www.symmons.com/service
Model number
S-46-2-BODY .. Temptrol Tub-Shower
mixing valve
S-46-1-BODY .. Temptrol Shower
mixing valve
Temptrol
®
Figure 1 Mounting plate
wall cutout hole size
3-1/2" (89 mm) min
4" (102 mm) max
Finished wall must be
ush with back side of
protective shield surface
nished wall
Dry wall, plaster or other type wall
1/2" (13 mm) or greater
Protective shield
"snap on-off"
(required when
mounting plate
is not used)
2-3/8"
±
1/2"
(60 mm
±
13 mm)
pipe centerline
to nished wall
wall cutout hole size
3-1/2" (89 mm) min
4" (102 mm) max
nished
wall
Ensure valve’s
mounting plate
is ush against
inner wall
Walls for using T-177 mounting plate
Fiberglass or acrylic walls (required)
Plaster or other type walls (optional)
1/16" (2 mm) min 1/2" (13 mm) max
p/n T-176
p/n T-177
Protective shield
When mounting plate is used,
then shield is optional for
protecting end of valve during
installation.
"snap on-off"
Figure 2 Mounting valve
Rough-in Installation
Installing control valve, piping & fittings
Reference rough-in dimension illustration
on page 2 as required.
Important!:
Use alternate dimension
gures when installing escutcheon trim
listed in the table below.
1) Determine wall thickness
Determine type of wall and wall
thickness where valve will be mounted.
Consider whether to use mounting plate
by reviewing gure 2 below.
Skip ahead to Step 3 if mounting
plate will not be used.
2) Attach mounting plate to valve
Seat mounting plate against valve
assembly as illustrated in gure 1.
3) Attach protective shield
Reference gure 2 to determine
whether shield is required.
Attach plastic protective shield
by snap tting over end of valve
spindle.
4) Install piping, fittings and
control valve
Piping and ttings not supplied
Control Valve
Install valve through cutout hole in
wall as specied in gure 2 below and
dimension illustration on page 2.
Showerhead (S on valve)
Pipe from outlet port on valve marked S
to showerhead mounting arm location.
Hot & Cold Supply (H & C)
Pipe hot water supply to valve input
marked H and cold water supply to
valve input marked C.
Tub Spout (T on valve)
Pipe from outlet port on valve marked
T to tub spout. (S-46-2-BODY only)
Tub/Shower Mixing Valves
Installation Brief
S-46-2-BODY, S-46-1-BODY
1 2 3 4
Pipe
Sealant
Plumbers
Putty
Oxford 2" (51 mm)
±
1/4" (
±
6 mm)
Carrington 2" (51 mm)
±
1/2" (
±
13 mm)
Canterbury 2" (51 mm)
±
1/2" (
±
13 mm)
Temp Com 2" (51 mm)
±
1/2" (
±
13 mm)
Trim Series Pipe centerline to nished wall

Summary of content (4 pages)