Installation & Safety Instructions
60W
J-BOX
(3)
FIGURE 1
150W
TRACK & CABLE
(8) FUSED PLUGS
(8)
FIGURE 2
TRIM INSTALLATION
1. Cut wire to desired length.
2. Split ends of wire about (1/2”) and insert each end of
the wire as far as possible into the plug. Do not strip
any insulation o the wire.
3. Insert contact into one end of plug and press, or use
pliers until contact is
ush with plug. Repeat with other
contact (see illustration).
4. Twist wires sideways, insert into notch in plug and twist
back straight.
5. Snap plug on cable.
6. Install lamp (18w max.)(not included).
1. Secure trim (not included) to
housing by inserting
hooks, on trim, into two of the four slots in
housing and twist clockwise until trim snaps in place.
Bend hooks up slightly (max. 1/8”) if trim is too hard to
turn and lock into position on housing.
WARNING: Use of other manufacturers components
will void warranty, safety listing and create a
potential safety hazard.
RISK OF FIRE: DO NOT REMOVE REFLECTOR.
CAUTION: RISK OF FIRE. 12V LAMPS MUST NOT BE USED IN A
24V SYSTEM. INSTALL CABLE SO THAT CAUTION PRINTED ON
CABLE IS VISIBLE AFTER INSTALLATION AND ATTACH THE 24V
CAUTION LABELS (SUPPLIED WITH THE 24V TRANSFORMER) ON
OR ALONG THE TRACK EVERY 4 FT.
FINAL INSTALLATION AND FUSING
ATTENTION: RISQUE D'INCENDIE. UTILISER SEULEMENT 12V LAMPES
AVEC LES SYSTÈMES 12V. UTILISATION DE LAMPES 12V 24V SYSTEME
PEUT PROVOQUER DES DOMMAGES AU SYSTÈME ET ALENTOURS
FUSED PLUG INSTALLATION (NOT INCLUDED)
There are several ways to install (disk-lights) using
the 18w, 12V xenon lamps(actual consumption =
16.2w):
1. When using a 60w max transformer (class II)
you are able to directly hook up three (3) to
the junction box as in Figure 1.
2. For a run larger than three (3) disk-lights you
must use a class I transformer (larger than
60w). The following example demonstrates a
run of eight (8) disk-lights (8 x 16.2weach =
130w), in this case you will need to usea
150w transformer.
3. Disk light is supplied with 72” of cord and aplug
for connection to a plug in transformer.
Figure 2 demonstrates fusing each individual disk
light, with a fused plug.
(UTILISER UNIQUEMENT AVEC LE CÂBLE 105
)
ATTENTION-RISQUE D'INCENDIE MAX 18 WATT TYPE WEDGE T5
(USE ONLY WITH AMBIANCE 105
)
CAUTION-RISK OF FIRE MAX 18 WATT TYPE WEDGE T5