Install Instructions

SYNCOMM Proprietary
3
1.3. Installation on the wall
1.3.1.Installation requirements
It would be better that the wall is 8-inch thick. Because the
adopted fixed crew is only for cement wall use, the other materials
such as wooden wall and metal wall are not applicable
1.3.2.Installation procedures
Step1:
According to figure 5-2, assemble components (3) and (4) for two
sets (left and right) by M6*40 screws with grommet or spring
grommet between the screw and screw nut using components (7),
(8), (9), and (10).
Step2:
According to figure 5-2, drill two holes on the wall by electrical
driller with fitting size measured from the metal rack. Then fix the
component (2) on the wall by component (12).
Step3:
Assemble the two combined entities (left and right) from Step1 with
component (2) by M6*20 screws with grommet or spring grommet
between the screw and screw nut using components (7), (8), (9),