l Performance
Monitoring
The overall status of the RP is reported back to the RPCU
when a failure occurs.
Transmission Characteristics
l
RF Output Power
at antenna
terminal
800 mW (+29 dBm). The output power is con
trollable in four
steps, from 0 mW to 800 mW.
l
Adjacent channel
power emission
Less than 8 µW at +/- 600 kHz
Less than 2.5 µW at +/- 900 kHz
l Spurious
Emission
Less than -13 dBm on transmission band
Less than -74 dBm on receiving band
Complies to FCC standard on other band
l Output Impedance
50 ohms (nominal)
Receive Characteristics
l Receiving
sensitivity
Better than -101 dBm at 25
o
C (WER :3%, static)
l Selectivity More than 0 dB at +/- 300 KHz at 25
o
C
More than 50 dB at +/- 600KHz at 25
o
C
l Antenna diversity
2-
branch antenna selection diversity. One antenna supports
duplex receive and transmit. The other only supports receive.
Mechanical Specifications (Reference Only)
l Dimensions 39 cm (W) X 25 cm (H) X 9 cm (D)
l Weight Less than 10 kg (doesn't include antenna and cable)
l Power supply Line Powered from RPCU. No Separate Battery Backup