Data Sheet

SBF50xM Datasheet
Confidential Syntronix Corporation 9
4. DC Power Connection
MODE
Description
MIN
TYP
MAX
Unit
Typical DC-DC power connection,
CPU running at 26MHz and no RF
active
1.81
mA
Typical DC-DC power connection,
CPU running at 26MHz and
advertising interval 20ms (0dBm)
2.3
mA
Typical DC-DC power connection,
CPU running at 26MHz and
advertising interval 1s (0dBm)
0.101
mA
Typical DC-DC power connection,
CPU running at 26MHz and
connection interval 50ms (0dBm)
0.514
mA
Typical DC-DC power connection,
CPU at 32.768KHz Sleep Mode
0.217
mA
Typical DC-DC power connection,
CPU at 32.768KHz Deep-Sleep
Mode (ECO mode)
0.209
mA
Typical DC-DC power connection,
CPU at Power standby Mode
0.208
mA
Typical DC-DC power connection,
CPU at SPU Sleep Mode
39.7
uA
Typical DC-DC power connection,
CPU at SPU Deep-sleep Mode
29.8
uA
Typical DC-DC power connection,
CPU at SPU Power Down Mode
0.9
2
uA
Typical DC-DC power connection,
CPU at SPU Deep Power Down
Mode
0.6
0.8
uA
Table 4-1 DC power Connection