User's Manual

SYRIS active RFID TAG Instruction
5
3. How to replace the battery:
First, you need to screw the lid off tag by the proper screwdriver. And than, put the
new battery properly into the battery bracket which is mounted on the main board.
Like as below photo.
4. Set Parameters:
You can set TAG emitting frequency, receive frequency, ON/OFF Tag and LED
indication with SYRIS Xtive utility. (Please refer to
Xtive Utility user manual)
5. Battery Life:
Battery life is affect by TAG emitting frequency and receives frequency. Increasing
emitting/receives frequency will shorten the battery life.
Ex.
Battery life for 3 month setting :
Set TAG active time = 1 x 2.5 sec, Set Tag Receive Count =10
Battery life for 1 year setting :
Set TAG active time = 1 x 20 sec, Set Tag Receive Count =10