User's Manual

SHENZHEN SYS IoT CO., LTD. 24 / 34
Tel: 0086-755-82706913
Fax: 0086-755-82706900
Mail: sales@sysiot.cn
Http://www.sysiot.cn
Add: Room 716, Yiben E-Commerce
and Industrial Park, Chaguang Road
Nanshan District, Shenzhen, China
Post Code518055
Picture45
As shown in the above figures, in data result “82 F8 34 00 E2 00 10 26 77 01 01 75 26 AA BB
CC”, CRC=0x82F8, PC=0x34, EPC=0xE20010267701017526AABBCC. EPC data start from byte
0x0002.
3.5.3.3 Write data into USER Block
As mentioned in 3.5.3.1, result of Read shown as below picture, Picture46.
Picture46
Change the data in the Data bar, Shown as Picture47.
Picture47
Click “Write”, and Status bar will show “Write Memory Success”. Shown as Picture48.
Picture48
Click “Read” to check if the write operation is success or not, If success, the status bar will show
“Read Memory Success”, Shown as Picture49.