System 1738 Installation Methods2
Supplemental information – DO’S and DON’TS
Refer to the contents of this guide for complete
instructions and guidelines.
CAUTION
DO’s
Read the appliance and vent manufacturer’s installation
instructions and install product accordingly
Follow recommended safe work practices
System 1738 may only be used for venting categories II and
IV appliances generating a maximum flue gas temperature
of 149
o
F (65
o
C)
Make certain that fire-stop materials are compatible with
System 1738 product
Keep pipe and fittings clean and in original packaging until
needed
If pipe and fittings are stored outdoors, cover with a well-
ventilated white tarp and never store other products on
top of pipe
Follow handling and storage procedures found in this guide
Only use tools, on System 1738 pipe and fittings, as
described in this guide
Use a drop cloth to protect interior finishes
Cut the pipe ends squarely
Deburr and bevel the pipe end with a chamfering tool
before solvent welding
Check joint and seams for gas tightness
Slowly rotate the pipe a quarter turn when inserting pipe in
fitting socket when solvent welding
Avoid puddling of solvent cement in fittings and pipe
Ensure excess primer and solvent cement does not run
inside pipe and fittings
Follow System 1738 recommended set times found in this
guide before commissioning the vent system
Allow for movement due to expansion and contraction
Only use products listed to UL 1738 for venting or
combustion gases.
Contact Local Building or Fire Officials about restrictions
and installation inspection in your area.
Always adhere to local jobsite and workplace safety
regulations.
DON’Ts
DO NOT mix pipe, fitting or joining methods from
different manufacturers
DO NOT use solvents or cements other than what
is required by this guide
DO NOT install adhesive tape, insulated wire, or
cable in direct contact with System 1738 product
DO NOT use solvent cement that has exceeded
its shelf life or has become discolored or jelled
DO NOT drill System 1738 pipe
DO NOT use solvent cement near sources of heat
or open flame, or when smoking
DO NOT subject vent system to compressed air
DO NOT cut pipe with dull or broken cutting-tool
blades
DO NOT use ratchet cutters or reciprocating saw
to cut pipe
DO NOT use System 1738 product that’s been
stored unprotected outdoors and is faded in
color
DO NOT allow threaded rod to come in contact
with the pipe; for example, threaded rods used to
connect pipe hangers
DO NOT use PVC/CPVC pipe and fittings listed for
plumbing applications for venting of combustion
gases