Manual Thermoplus

Thermoplus
23
EN
Adaptive function
The thermostat has a function which works
out when the heating should start to give the
correct temperature at the correct time. It is
activated on delivery, but can be turned off:
Press
and navigate to SET.
Select with
Navigate to AF,
Select with
Navigate between ON/OFF.
Confirm with
Ventilation mode
If the room temperature falls by more than
3 °C in a single minute, e.g. when airing the
room, the ventilation mode is activated.
The thermostat will then stop heating for 15
minutes before returning to normal mode.
This function is always active.
Press
to select. The display now shows the
operation time as a percentage for the last
24 hours. You can then navigate between the
operation time as a percentage for the last
7/30/365 days.
Press
and navigate to UTIL.
Delay between turning off and on
There is a built-in delay in order to avoid
unnecessary wear and tear on internal
components and to extend the life of
the thermostat. If you raise the desired
temperature so that the thermostat comes on,
and then lower it shortly afterwards, it takes
30 sec before it goes off again.
Operation time
The thermostat can display the operation
time as a percentage for the last 24 hours and
7/30/365 days.
Green light – the thermostat is on and the
heat is turned off.
Red light – the thermostat is on and the heat
is turned on.
Flashing green and red lights – error
indication. The heat is turned off. The
thermostat shows the error message until it is
turned off.
No light – the thermostat is switched off or is
not getting any power.
LED
The LED allows you to see the current status
of the thermostat.