Original instructions Bench heater SH EN .... 8 RU ....18 SE .... 10 NO ....12 FR .... 14 DE ....
Bench heater SH Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not apply to all application areas. The Regulation applies when an installation is intended to provide thermal comfort for people in the premises. The Regulation does not apply to heating installations of a more technical nature e.g. in engineering/utility rooms, in production processes, frost protection, etc. The Regulation also does not apply to installations in vehicles, offshore or outdoors.
Bench heater SH 41,5 200 L SH17521/SH17531 L [mm] 700 SH25021/SH25031 1000 SH37521/SH37531 1500 Minimum distances EN: SE: NO: FR: DE: RU: Minimum distances Minimiavstånd Minsteavstand Distances minimales Mindestabstand Минимальные расстояния при установке 3
Bench heater SH Bench heater SH (IP21) Item number Type Output [W] Voltage [V] Amperage [A] LxH*xW [mm] Weight [kg] 10201 SH17521 175 230V~ 0,8 700x110x200 1,4 10202 SH17531 175 400V~ 0,4 700x110x200 1,4 10203 SH25021 250 230V~ 1,1 1000x110x200 1,9 10204 SH25031 250 400V~ 0,6 1000x110x200 1,9 10206 SH37521 375 230V~ 1,6 1500x110x200 2,9 10207 SH37531 375 400V~ 0,9 1500x110x200 2,9 *) Height with brackets EN: SE: NO: FR: DE: RU: Heigth with brackets Höjd med
Bench heater SH Wiring diagrams Internal wiring diagrams 230V ~ 400V ~ SHxxx21 SHxxx31 NL1L2L3 NL1L2L3 Control by thermostat 230V~ 230V TAP16R °C SENSOR SENSOR LOAD N LOAD L TAP16R 230V~ SHxxx21 SHxxx21 NL1L2L3 SHxxx21 NL1L2L3 NL1L2L3 5
Bench heater SH Control by thermostat 400V~ 230V TAP16R °C SENSOR SENSOR N LOAD LOAD L TAP16R 230V ~ A1A2 L1 L2 L1 T1 L2 T2 L3 N L3 T3 N N RB3 SHxxx31 SHxxx31 NL1L2L3 6 SHxxx31 NL1L2L3 NL1L2L3
Bench heater SH Frico control 230V~ Sensor GND B1 B2 0-10V OUT FCPOBH A1 A2 GND G 1 2 GND Sensor FCBB FCRTX FCOTX Sensor G 1 2 FCCH HI LO HI BUS 2 LO GND +12V GND BUS 2 LO +12V BUS 1 L2 L2 PE PE LIN N N LOUT HI +12V GND BUS 1 LO HI +12V GND 230V~ Max 16A SHxxx21 SHxxx21 NL1L2L3 NL1L2L3 Frico control 400V~ Sensor GND B1 B2 0-10V OUT FCPOBH A1 A2 GND G 1 2 GND Sensor FCBB FCRTX FCOTX Sensor G 1 2 FCCH HI LO HI BUS 2 LO GND +12V GND BUS 2 LO +12V BUS 1 L2 L2 PE PE L
EN Bench heater SH Installation and operating instructions General Instructions Read these instructions carefully prior to installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid should the product be used in the manner intended and in accordance with the instructions. Application Bench heater SH is designed for use with church pews, waiting room benches and the like.
Bench heater SH EN Safety • For all installations of electrically heated products a residual current circuit breaker 300 mA for fire protection should be used.
Tel: +46 31 336 86 00 mailbox@frico.se www.frico.net For latest updated information and information about your local contact: www.frico.