Installation, Operation and Maintenance instruction K Circular duct fan AC/EC KV Circular duct fan for wall AC/EC Prio Circular duct fan AC/EC EN
Table of content 1 Introduction .......................................................... 1 1.1 Product description ...................................... 1 1.2 Intended use .............................................. 1 1.3 Document description................................... 1 1.4 Product overview K fan and KV fan.................. 1 1.5 Product overview prio fan .............................. 2 1.6 Name plate ................................................ 2 1.6.1 Type designation ...............
1 Introduction 1.1 Product description in outdoor environments with weather protection. The product is applicable for ambient temperatures of between -25 ° C and +70 °C. K fans, KV fans and prio fans are made for installation in circular duct systems. This product is a circular duct fan with an airtight casing made from sheet metal. The product is not supplied with a safety switch, external speed control, or FK fast clamps, these parts are available and recommended as accessories.
1.5 Product overview prio fan 1 2 3 4 5 6 1. 2. 3. Connection box Airflow direction arrows Name plate 1.6 4. 5. 6. Name plate 1 2 3 Fan impeller Casing Mounting bracket Note: 4 5 6 The data on the name plate applies to “standard air” that is specified in the standard ISO5801. 14 13 12 11 10 9 8 7 1. Type designation: Product name, dimension and motor type. Refer to 1.6.1 Type designation page 3. 2. Input power, W 3. Frequency, Hz 4. Certifications 5. Scannable code 1 6.
1.6.1 Type designation 2 Safety Safety definitions Product name K KV prio 2.1 Dimension 100 100 315 Warnings, cautions and notes are used to point out specially important parts of the manual.
• Read this manual and make sure that you understand the instructions before you do work on the product. • Obey local conditions and laws. • The ventilation contractor and the operator are responsible for correct installation and intended use. • Keep this manual at the location of the product. • Do not install or operate the product if it is defective. • Do not remove or disconnect safety devices. • Make sure that you can read all warning signs and labels on the product when it is installed.
4 Installation 4.1 To do before the installation of the product • Make sure that you have the necessary installation accessories: – Refer to 13 Accessory overview page 30 for an overview of the accessories. – If you install the product outdoors, it is necessary to install a weather protection roof. – To decrease vibrations transmitted from the product to the duct system, Systemair recommends to install vibration dampers, fast clamps or flexible connections. 4.
Product type Screw X (mm) K 100 M 3 112.5 K 125 M 3 112.5 K 100/125 XL 1 124.5 K 150/160 M 2 148.5 K 150/160 XL 1+3 174.5 K 200/250 M 1+2 183.5 K 200/250 L 1+2 183.5 K 315 M/L 1+2 222 K 100 EC 1 124.5 K 125 EC 1 124.5 K 150 EC 2 148.5 K 160 EC 2 148.5 K 200 EC 1+2 183.5 K 250 EC 1+2 183.5 K 315 EC 1+2 222 4.3 1 2 To install the prio fans Attach the pendulum bars or wires to the mounting brackets on the product casing. 4.
2 Use the fast clamps (A) to attach the duct to the product. Systemair recommends to use FK fast clamps to attach the duct to the product. The FK fast clamps are available as an accessory. 5 Electrical connection 5.1 To do before the electrical connection Refer to13 Accessory overview page 30 . • Make sure that the electrical connection agrees with the product specification on the motor name plate. • Make sure that the environment for electrical connection is clean and dry.
5.6 To install motor protection for AC motors 6 Commissioning Caution • If the product has an built in motor protection, reset by disconnecting the product from power for 60 seconds. • If strong vibrations occur during commissioning, immediately increase or decrease the fan speed until the vibrations are decreased. Continuous strong vibrations can cause damage to components.
7 Operation Caution EC motors must be set to ON/OFF via the control input. To stop the product via mains supply decreases the life time of the motor. Systemair recommends to install external speed controller for easy access to control the input signal. 7.1 To start a product with an EC motor 1 Make sure that the 0–10 V signal is set to “0” with the speed controller. 2 Set the installed safety switch in the ON position and wait 5 seconds.
Maintenance task Usual operation conditions Each 6 months Each 3 months Each 6 months Visually examine the product and its components for damage, corrosion and dirt. X X Examine the fan impeller for damage and imbalance. X X Clean the product and the ventilation system. X Do a check of all fasteners and make sure that they are fully tightened. Make sure that the product and its components are correctly operated.
9 Troubleshooting Note: If you cannot find a solution to your problem in this section, speak to Systemair technical support. Problem Cause Solution The fan impeller is not correctly balanced. Speak to Systemair technical support. There is dirt on the fan impeller. Clean the fan impeller carefully. Refer to 8.2 To clean the product page 10. The fan impeller has damages or deformations because the transported air contains aggressive media. Speak to Systemair technical support.
Problem Cause Solution The fan impeller does not turn in the correct direction. Make sure that the electrical connection is correctly done. A phase loss occurred. If the motor is a 3-phase motor, make sure that no phase is missing. Note: This is not applicable for EC motors. The motor is overheated. Thermal contacts, PTC or resistors are released. • Do a check of the motor cooling impeller. • If it is possible, measure the resistance to do a check of the motor winding.
10 Disposal The product follows the WEEE directive. This symbol on the product or the packaging of the product shows that this product is not domestic waste. The product must be recycled at an approved disposal location for electrical and electronic equipment. 11 Warranty For warranty claims, send a written maintenance plan and the commissioning report to Systemair. The warranty is only applicable for these conditions: • The product is correctly installed and operated. • Motor protection is used.
12 Technical data 12.1 Technical data overview Max. temperature of transported air, °C 70 Max. ambient temperature, °C 70 Sound pressure, dB Refer to the data sheet in the online catalogue at www.systemair.com. Corrosion class IP class Voltage, current, frequency, enclosure class, weight Refer to the name plate. Refer to 1.6 Name plate page 2 for more information. Motor data 12.2 Refer to the motor name plate or the technical documentation from the motor manufacturer. Product dimensions 12.2.
ØA ØB C D E F G H K 250 L sileo 336 249 27 30.5 202 144.5 40 88 K 315 sileo 408 314 27 32.5 220 160.5 40 88 K 315 M sileo** 1 408 314 27 32.5 220 160.5 40 88 K 315 L sileo** 1 408 314 27 38 225 161 40 88 1. ** after the product name means that the product is sold outside EU.
A B C ØD ØE F G H KV 200 L sileo 5 158 30 199 336 40 394 425 KV 250 M sileo 5 135 30.5 249 336 40 394 425 KV 250 L sileo 5 159 30.5 249 336 40 394 425 KV 315 sileo 5 145 32.5 314 408 40 458 489 KV 315 M sileo** 1 5 145 32.5 314 408 40 458 489 KV 315 L sileo** 1 5 145 37.5 314 408 40 458 489 1. ** after the product name means that the product is sold outside EU.
A B ØC D E ØF G H I ØJ ØK prio 315 45 100 459 15 357 10 60 676 45 313 407 prio 355 45 100 459 15 335 10 60 632 45 353 407 prio 400 45 100 459 15 266 10 60 493 45 399 407 A B ØC D E ØF G H I ØJ ØK prio 315 EC 45 100 375 15 205 10 60 407 45 314 322 prio 355 EC 45 100 459 15 335 10 60 632 45 353 407 prio 400 EC 45 100 459 15 266 10 60 493 45 399 407 H I A B C J K L D E G F A B C D E ØF G H I ØJ ØK
Wiring diagrams Abbreviation in wiring diagram Cable colour RD Red YE Yellow BU Blue WH White GN Green BN Brown BK Black GR Grey GY Green/Yellow Wiring diagrams for AC fans KV fans K 100 M sileo KV 100 M sileo K 125 M sileo KV 125 M sileo K fans KV fans K 100 XL sileo KV 100 XL sileo K 125 XL sileo KV 125 XL sileo K 150 M sileo KV 150 M sileo K 150 XL sileo KV 150 XL sileo K 160 M sileo KV 160 M sileo K 160 XL sileo KV 160 XL sileo K 200 L Sileo KV 200 L sileo K 200
prio fans 1–phase 230 V prio 315 prio 355 C N TK TK L prio 400 GY GY BN BU BK YE/GN prio fans 3–phase 230 V 3–phase 400 V prio 450 TK TK L1 L2 L3 TK TK L1 L2 L3 prio 500 TK TK W2 U1 U2 V1 V2 W1 12.3.2 TK TK W2 U1 U2 V1 V2 W1 Wiring diagrams for EC fans Note: An internal potentiometer is installed on the terminal block from the factory. Remove the internal potentiometer when you use an external speed controller for the EC fan.
prio fans 3–phase 400 V prio 400 EC prio 500 EC 10V 0-10V GND RSA RSB RD YE BU WH BN NC COM L2 L2 L3 WH WH BK BK BK YE/GN prio fans prio 450 EC prio 500 EC D1 D1 10V 10V E1 E1 GND GND 24V 24V B E1 0-10V DC C 10k D D L3 L3 L2 L2 L1 L1 11 11 A 14 A. A 14 11 & 14 = Alarm For operation: the relay is energized, connections 11 and 14 are bridged For fault: the relay is de-energized (diagnostics/faults) Contact rating maximum AC 250 V 2 A B. External potentiometer C.
RE Manual 5-step transformer. RE 1,5 ~ RE 3 N RE 5 RE 7 ~ N A N B C D A. Relay connection. There is always 230 V between ~ and N when the transformer knob is in one of the positions 1–5. B. Mains supply C. Earth D. Fan REE — Thyristor REE 1 and REE 2 - Surface mounting or with flush mounting casing included. REE 4 - Surface mounting. N Note: Starting currents must be considered when you select the speed controller type.
RTRE Manual 5-step transformer with motor protection. RTRE 1,5 RTRE 3 ~ ~ N RTRE 5 N N B C Rt D Rt Tk Tk E F A RTRE 7 RTRE 12 ~ N ~ N A N B C Rt D Rt Tk Tk E F A. Relay connection. There is always 230 V between ~ and N when the transformer knob is in one of the positions 1–5. B. Mains supply C. Earth D. Fan E. Thermostat F. Motor protection. If the motor protection is not in use, Tk must be looped together.
A. Contact rating, maximum AC 250 V/2 A B. Mains supply, 1–phase 208...277 V, 50/60 Hz C. Motor with internal thermal contacts D. OFF/ON RTRD A 3-phase transformer that controls the fan speed by altering the supply voltage in five fixed steps. The steps are adjusted by using the control knob on the front of the unit. RTRD2-7 N L L RT RT FS FS TK TK A A B N L1 L2 L3 N L1 L2 L3 U V W A 230 V AC PE U W TB TB C D A.
RTRDU Manual 5–step transformer with motor protection — a 3–phase transformer that controls the fan speed by altering the supply voltage in five fixed steps. The steps are adjusted by using the control knob on the front of the unit. RTRDU A 0 B 0 5 15 4 24 3 1 1 2 3 2 3 N L L RT RT FS FS TB TB A A N L1 L2 L3 PE N L1 L2 L3 U V W A 230 V AC max. 1 A 230 V AC U F B 01 TB TB C D E A. If the function is not necessary, the terminals must be bridged B.
MTP 20 MTP 20 1/Vdc+ +10V 4/Vout 0...10V 2/Vdc- GND 3/Vout- EC-Basic EC-Basic 1/IN Vac 230V AC 2/IN Vac +10V 4/Out 0...10V 5/GND GND MTV–1/10 MTV 1/010 1/IN Vac 230V AC 2/IN Vac +10V 4/Out+ 0...10V 5/Out- GND S-5EC/FRQ MTP 10 10V +10V GND 0...10V A GND EC-Vent EC-Vent IN/RPM optional IN/10V OUT/PWN GND TACH +10V PWM 0...
12.3.5 Wiring diagrams for ON/OFF controls for EC motors CO2RT-R(-D) CO2RT-R-D Supply +10V Neutral 0...10V Common GND 24V AC Relay NO Relay NC Din1 IR24–P IR24-P 24V +10V Neutral 0...10V Common GND 24V AC or DC Relay NO Relay NC 12.3.6 Din1 Wiring diagrams for demand control for EC motors EC Basic EC Basic-T for temperature control EC Basic-CO2/T for temperature and CO2 control EC Basic-H for humidity control EC-Basic 1/IN Vac 230V AC 2/IN Vac +10V 4/Out 0...
EC-Vent Demand control for up to 5 external sensors, 2 fans, dampers, heaters and coolers. The EC vent system has 2 units. The control board (CB) and the room unit (RU). Connect the fan to the control board and remove the internal potentiometer. EC-Vent IN/RPM optional TACH IN/10V OUT/PWN +10V PWM 0...
Control Board (CB) I 5 (GND) 6 (0-10V) 7 G + DC MAX 24V I max 50mA H 2 (+24VDC) 3 (0-10V) 1 (GND) 1 (tach output) 2 (GND) 3 (PWM) 4 (+10VDC) N L F OUT3 OUT2 24V D A GND ALARM FAN 24V D A GND E OUT1 IN2 C B IN2 WY +0-10V Br + 24VDC GND A/D PT1000 24V GND A/D PT1000 24V GND A/D PT1000 24V N out N in L out L in A A. Mains supply, 230 V 1~AC (10 A) B. Analogue sensor (for example, pressure sensor) C. Analogue sensor (for example, pressure sensor type PT1000) D.
MM6-24/D output signal selector Compares signals from connected inputs and transfers the signal to the control output. 1 Input 1 0...10 V 2 Input 2 0...10 V 3 Input 3 0...10 V 4 Input 4 0...10 V 5 Input 5 0...10 V 6 Input 6 0...10 V 7 System neutral 8 24 V AC 9 Signal neutral 10 Signal neutral 11 Output minimum 0...10V 12 Output maximum 0...10V Mains supply PCA 1000D2 Pressure controller PCA 1000/6000D2 R i = 4 kΩ p PI V 1(+) 2( ) +US GND A GND + ∆p - + US 3 1 01 10...
13 Accessory overview 5 4 3 1 2 7 5 6 10 11 8 9 12 1. 2. 3. 4. 5. 6. IGK: inlet louvre IGC: inlet louvre RSK: Back draft damper FGR/FFR: Filter cassette FK fast clamp Fan 7. 8. 9. 10. 11. 12. LDC: Silencer CWK: Water cooling battery VBC: Water heating battery CB and CBM: Electrical duct heaters SPI: Iris damper Balance S supply air diffuser Note: For more information about accessories, refer to www.systemair.com or speak to Systemair technical support.
14 EU Declaration of Conformity We, the manufacturer Manufacturer Systemair Sverige AB Address Industrivägen 3 739 30 Skinnskatteberg Sweden declare under our sole responsibility that the products Machine Circular duct fan Type/Model K, KV, prio fulfils the relevant provisions of following directives and standards Machinery Directive 2006/42/EC EN ISO 12100:2010 Safety of machinery – General principles for design - Risk assessment and risk reduction EN ISO 13857:2019 Safety of machinery – Safety d
15 UK Declaration of Conformity We, the manufacturer Manufacturer Systemair Sverige AB Address Industrivägen 3 SE-73930 Skinskatteberg Sweden declare under our sole responsibility that the products Machine Circular duct fan Type/Model K, KV, prio fulfils the relevant provisions of following directives and standards Supply of Machinery (Safety) Regulations 2008 EN ISO 12100:2010 Safety of machinery – General principles for design - Risk assessment and risk reduction EN ISO 13857:2019 Safety of mach
33
last page Systemair Sverige AB Industrivägen 3 SE-739 30 Skinnskatteberg +46 222 440 00 mailbox@systemair.com www.systemair.com © Copyright Systemair AB All rights reserved EOE Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications.