Operation and Maintenance Instructions
Table Of Contents
- 1 Overview
- 2 Warnings
- 3 Warnings signs on product
- 4 Product description
- 5 Start up
- 6 Operation
- 7 Maintenance
- 7.1 Maintenance intervals
- 7.2 How to replace supply/extract air filter
- 7.3 How to clean NaviPad
- 7.4 How to clean the heat exchanger
- 7.5 How to clean the fans
- 7.6 How to clean hot water heating coil
- 7.7 How to clean the electric heating coil
- 7.8 How to clean the extract air louvres and inlet diffusers
- 7.9 Clean the outdoor air intake
- 7.10 How to clean the duct system
- 7.11 Where to reset tripped fuses
- 7.12 How to reset the manual overheat protection (EL units)
- 7.13 How to replace the fan module
- 7.14 How to replace the heat exchanger
- 7.15 Change the internal battery in control unit CU27–C
- 8 Troubleshooting
- 9 Alarms
- 10 Service
- 11 General conditions
- 12 Spare parts
18
|
Operation
6.2 Advanced HMI (Human Machine Interface) Settings
Return to system overview dashboard by pressing on the NaviPad button,. Go to and choose
Advanced HMI settings. Login required — 1111
NaviPad settings
2022–02–04
Home
Unit name
Normal operation
Language
Time & Date setting
Advanced HMI
settings
Restart NaviPad
• Available devices (air handling units) (Example 8)
• Change Password
• Ethernet setting: IP address can be configured to either obtain an IP address from a DHCP server (dynamic) or set
manually as a static IP address
1
• Restore NaviPad Factory Settings (Example 9)
• Restart NaviPad
1
For further support setting a static IP address, see “Access Manual Communication”
Example 8: Available devices (air handling units)
Home > Advanced HMI settings > Available decives
2022–02–04
192.168.41.38
Select device
Serial number:
012345678910
IP Address:
192.168.41.116
Name:
Unit name
Serial number:
058345678919
IP Address:
192.168.41.49
Name:
Unit name
The air handling unit will appear, press the button to select the air handling unit to pair it with the NaviPad. If there are
several air handling units at the same IP subnet, a list of available air handling units will be presented.
The IP address of NaviPad itself is presented above the Select device header
The Access system support up to nine air handling units being paired to one NaviPad, to be viewable in its system over-
view dashboard of the same network.
Note:
The use of a web browser to examine the air handling unit’s interface is supported with one web browser
together with two paired NaviPad. If that number of connection is exceeded, one or several of the following
will happen:
• periodically flashing red NaviPad button, despite no unacknowledged alarm.
• symbol telling no communication on NaviPad.
• red marked error fields for real-time values of the air handling unit user interface.
In systems with several air handling units monitored in a system dashboard, it’s recommended that this is done from
only one strategic placed NaviPad and let the other NaviPad on the same network only be paired with its own air han-
dling unit.