Communication Manual

APPENDIX EXCEL TABLE PRINTOUT
Access version: 4.6-1-00 rev. 2
Signal name
EXOL
Type
Modbus type
Modbu
s
addres
RW
Bacnet
Scale
factor
Unit
Function Description Release
Access variable list
More information can be found in the Communication Manual
AlaData.Ala_MalfunctionSAF7_Status
X
Input Register (3x)
0189
R
Alarm Status
Malfunction supply air fan 7
4.3-1-00
AlaData.Ala_MalfunctionSAF8_Status
X
Input Register (3x)
0190
R
Alarm Status
Malfunction supply air fan 8
4.3-1-00
AlaData.Ala_MalfunctionEAF6_Status X Input Register (3x) 0191 R 1 Alarm Status Malfunction extract air fan 6 4.3-1-00
AlaData.Ala_MalfunctionEAF7_Status
X
Input Register (3x)
0192
R
Alarm Status
Malfunction extract air fan 7
4.3-1-00
AlaData.Ala_MalfunctionEAF8_Status X Input Register (3x) 0193 R 1 Alarm Status Malfunction extract air fan 8 4.3-1-00
AlaData.Ala_AlarmSAF6_Status X Input Register (3x) 0194 R 1 Alarm Status Alarm supply air fan 6 4.3-1-00
AlaData.Ala_AlarmSAF7_Status
X
Input Register (3x)
0195
R
Alarm Status
Alarm supply air fan 7
4.3-1-00
AlaData.Ala_AlarmSAF8_Status X Input Register (3x) 0196 R 1 Alarm Status Alarm supply air fan 8 4.3-1-00
AlaData.Ala_AlarmEAF6_Status
X
Input Register (3x)
0197
R
Alarm Status
Alarm extract air fan 6
4.3-1-00
AlaData.Ala_AlarmEAF7_Status
X
Input Register (3x)
0198
R
Alarm Status
Alarm extract air fan 7
4.3-1-00
AlaData.Ala_AlarmEAF8_Status X Input Register (3x) 0199 R 1 Alarm Status Alarm extract air fan 8 4.3-1-00
AlaData.Ala_WarningSAF6_Status
X
Input Register (3x)
0200
R
Alarm Status
Warning supply air fan 6
4.3-1-00
AlaData.Ala_WarningSAF7_Status
X
Input Register (3x)
0201
R
Alarm Status
Warning supply air fan 7
4.3-1-00
AlaData.Ala_WarningSAF8_Status X Input Register (3x) 0202 R 1 Alarm Status Warning supply air fan 8 4.3-1-00
AlaData.Ala_WarningEAF6_Status
X
Input Register (3x)
0203
R
Alarm Status
Warning extract air fan 6
4.3-1-00
AlaData.Ala_WarningEAF7_Status
X
Input Register (3x)
0204
R
Alarm Status
Warning extract air fan 7
4.3-1-00
AlaData.Ala_WarningEAF8_Status X Input Register (3x) 0205 R 1 Alarm Status Warning extract air fan 8 4.3-1-00
AlaData.Ala_MalfunctionHeatingZone1_Status
X
Input Register (3x)
0206
R
Alarm Status
Malfunction heating zone 1
4.3-1-00
AlaData.Ala_MalfunctionHeatingZone2_Status X Input Register (3x) 0207 R 1 Alarm Status Malfunction heating zone 2 4.3-1-00
AlaData.Ala_MalfunctionHeatingZone3_Status X Input Register (3x) 0208 R 1 Alarm Status Malfunction heating zone 3 4.3-1-00
AlaData.Ala_MalfunctionCoolingZone1_Status
X
Input Register (3x)
0209
R
Alarm Status
Malfunction cooling zone 1
4.3-1-00
AlaData.Ala_MalfunctionCoolingZone2_Status X Input Register (3x) 0210 R 1 Alarm Status Malfunction cooling zone 2 4.3-1-00
AlaData.Ala_MalfunctionCoolingZone3_Status
X
Input Register (3x)
0211
R
Alarm Status
Malfunction cooling zone 3
4.3-1-00
AlaData.Ala_ControlErrorSupplyTempZone1_Status
X
Input Register (3x)
0212
R
Alarm Status
Deviation alarm supply air temperature zone 1
4.3-1-00
AlaData.Ala_ControlErrorSupplyTempZone2_Status X Input Register (3x) 0213 R 1 Alarm Status Deviation alarm supply air temperature zone 2 4.3-1-00
AlaData.Ala_ControlErrorSupplyTempZone3_Status
X
Input Register (3x)
0214
R
Alarm Status
Deviation alarm supply air temperature zone 3
4.3-1-00
AlaData.Ala_LowTempFrostGuardZone1_Status
X
Input Register (3x)
0215
R
Alarm Status
Freeze protection alarm zone 1
4.3-1-00
AlaData.Ala_LowTempFrostGuardZone2_Status X Input Register (3x) 0216 R 1 Alarm Status Freeze protection alarm zone 2 4.3-1-00
AlaData.Ala_LowTempFrostGuardZone3_Status
X
Input Register (3x)
0217
R
Alarm Status
Freeze protection alarm zone 3
4.3-1-00
AlaData.Ala_ElectricOverheatZone1_Status X Input Register (3x) 0218 R 1 Alarm Status Electric heater is overheated zone 1 4.3-1-00
AlaData.Ala_ElectricOverheatZone2_Status X Input Register (3x) 0219 R 1 Alarm Status Electric heater is overheated zone 2 4.3-1-00
AlaData.Ala_ElectricOverheatZone3_Status
X
Input Register (3x)
0220
R
Alarm Status
Electric heater is overheated zone 3
4.3-1-00
AlaData.Ala_SensorErrorTempSupplyZone1_Status X Input Register (3x) 0221 R 1 Alarm Status Sensor error supply air temperature zone 1 4.3-1-00
AlaData.Ala_SensorErrorTempSupplyZone2_Status
X
Input Register (3x)
0222
R
Alarm Status
Sensor error supply air temperature zone 2
4.3-1-00
AlaData.Ala_SensorErrorTempSupplyZone3_Status
X
Input Register (3x)
0223
R
Alarm Status
Sensor error supply air temperature zone 3
4.3-1-00
AlaData.Ala_SensorErrorTempRoomZone1_Status X Input Register (3x) 0224 R 1 Alarm Status Sensor error room temperature zone 1 4.3-1-00
AlaData.Ala_SensorErrorTempRoomZone2_Status
X
Input Register (3x)
0225
R
Alarm Status
Sensor error room temperature zone 2
4.3-1-00
AlaData.Ala_SensorErrorTempRoomZone3_Status
X
Input Register (3x)
0226
R
Alarm Status
Sensor error room temperature zone 3
4.3-1-00
AlaData.Ala_SensorErrorTempExtractZone1_Status X Input Register (3x) 0227 R 1 Alarm Status Sensor error extract temperature zone 1 4.3-1-00
AlaData.Ala_SensorErrorTempExtractZone2_Status
X
Input Register (3x)
0228
R
Alarm Status
Sensor error extract temperature zone 2
4.3-1-00
AlaData.Ala_SensorErrorTempExtractZone3_Status
X
Input Register (3x)
0229
R
Alarm Status
Sensor error extract temperature zone 3
4.3-1-00
AlaData.Ala_SensorErrorTempFrostZone1_Status X Input Register (3x) 0230 R 1 Alarm Status Sensor error freeze protection temperature zone 1 4.3-1-00
AlaData.Ala_SensorErrorTempFrostZone2_Status
X
Input Register (3x)
0231
R
Alarm Status
Sensor error freeze protection temperature zone 2
4.3-1-00
AlaData.Ala_SensorErrorTempFrostZone3_Status X Input Register (3x) 0232 R 1 Alarm Status Sensor error freeze protection temperature zone 3 4.3-1-00
AlaData.Ala_SignalErrorFeedbackCoolerValve_Status X Input Register (3x) 0233 R 1 Alarm Status Signal error feedback cooler valve 4.5-1-00
AlaData.Ala_SignalErrorFeedbackOutdoorDamper_Status
X
Input Register (3x)
0234
R
Alarm Status
Signal error feedback outdoor air damper
4.5-1-00
AlaData.Ala_SignalErrorFeedbackRecircDamper_Status X Input Register (3x) 0235 R 1 Alarm Status Signal error feedback recirculation damper 4.5-1-00
AlaData.Ala_DeviceWarning_Status
X
Input Register (3x)
0236
R
Alarm Status
Device warning
4.4-1-00
AlaData.Ala_DeviceAlarm_Status
X
Input Register (3x)
0237
R
Alarm Status
Device alarm
4.4-1-00
Page 5 of 45