OM Commercial Wall Panel Fans

1. Cut a hole through the wall to suit fan type. See diagram 1 and 6. Electrical Connections
dimensions D&E
ES6W and ES6P Models
Diagram 1 This model can only be wired for extract.
Connect the power into the terminal located on the rear of the fan.
Product A B C D E
ES6W 310 310 160-290 278 288
ES9W 390 390 160-290 361 366
ES12W 470 470 160-290 440 447
9" and 12" Fans Wall & Panel Models
The electrical connection using fixed wiring built into the wall is
2. Fit the telescopic sleeve into the wall. The sleeve is adjustable made via a 5 pin plug in connector (complete with cable grip)
and suitable for cavity or solid walls. ( A longer extension sleeve which is supplied with each fan unit for ease of electrical installation
is available to order) Make sure there is a slight tilt to the outside when connected to the incoming power cable it simply plugs into
to allow any water which may get in through the outside grille, the rear of the fan unit.
drain to the outside.
(IMPORTANT Ensure a minimum 300mm of power cable
is passed through the cable entry for the electrical
connections.)
NOTE (Diagram A)
The 6", 9" and 12" fans series can be wired
via 3 core cable for intake only.
3. Build in the sleeve and make good around the edges. The external
NOTE (Diagram B)
The 6", 9" and 12" fans series can be wired
and internal grilles have a flange that over hangs the sleeve. via 3 core cable for extract only.
NOTE (Diagram C)
If the 2 speed reversible controller is used
THE – PANEL RANGE
with the 9" and 12" fans only. 5 core cable is required
4. Is supplied without the sleeve and external grille. The series is (which is available separately).
designed as a replacement for existing installations and fits most
makes of sleeve and wall box with little or no modifications to the These fans are double insulated and do not require an earth.
existing wall box installations. See Diagram 2 for dimensions. All wiring must comply with current IEE regulations.
A double pole isolating switch, having a contact separation of
5. All models of the series are secured internally by 4 mounting at least 3mm in all poles, must be used with a 3amp fuse fitted.
screws, and secured externally by 4 mounting screws. After The fan must not be accessible to a person using either a bath
fixing the front and rear sections ensure you insert the hole plugs or a shower and mounted a minimum of 1.8m from the floor.
provided.
(IMPORTANT: Always ensure that the supply cable
cannot obstruct the fan blade.)
Diagram 2
Product A B C
ES6P 310 310 110
ES9P 390 390 138
ES12P 470 470 154