8
| Installation
Fig. 6 VTR 100/B LITE in a kitchen environment
A
Minimum distance between cabinets (mm)
600
B
VTR 100/B LITE unit width (mm)
561
C, Electrical stove Minimum distance between stove surface and cooker
hood (mm)
450 (Recommended 500)
C, Gas stove
Minimum distance between stove surface and cooker
hood (mm)
650
D
When flexible duct is used, distance between the unit
and cooker hood is decided by the installer (minimum
100 mm).
100
E
The cooker hood height (mm)
150
F
Total height of the unit with cooker hood connected by
minimum 100 mm flexible duct distance (D)
850
G
Distance to the mounting bracket from the underside
of the cooker hood or underside of the cupboard if it is
aligned with the cooker hood (mm)
Note:
This distance must be increased according to
the increased measurement D if flexible duct is
used.
815
Important!
The unit requires regular maintenance and therefore kitchen furniture panel between cabinets where the unit is lo-
cated must be removable.
Depending on the cupboard depth and selected kitchen furniture panel installation method, the VTR 100/B LITE unit
may have to me shifted forward using wood blocks at the back.
Solutions how to hang this panel are described further in this document, see 4.4 Installation of a kitchen furniture
panel, page 18.
Make sure to find a correct depth for installation of the VTR 100/B LITE unit before proceeding with the mounting
bracket installation on the wall.
The VTR 100/B LITE is supplied with approximately 1 m of power cable and fitted with a plug for 230 V~, single phase
earthed connection located at the top of the unit.
212962 | v02