VTR 100B LITE Installation and Service manual v2

Table Of Contents
12
| Installation
4.3 Installation with 392–10/B cooker hood
The VTR 100/B LITE is to be mounted above a stove.
Continue to follow instructions how to find the correct height and depth for mounting bracket installation.
Fig. 11 VTR 100/B LITE in a kitchen environment
A
Minimum distance between cabinets (mm)
600
B
VTR 100/B LITE unit width (mm)
561
C, Electrical stove Minimum distance between stove surface and cooker
hood (mm)
450 (Recommended 500)
C, Gas stove
Minimum distance between stove surface and cooker
hood (mm)
650
D
Distance between the unit and the cooker hood when
it is inserted directly into the unit (mm)
Note:
When flexible duct is used, distance between
the unit and cooker hood is decided by the
installer (minimum 100 mm).
10
E
The cooker hood height (mm):
97
F
Total height of the unit with inserted cooker hood
(mm):
707
G
Distance to the mounting bracket from the underside
of the cooker hood or underside of the cupboard if it is
aligned with the cooker hood (mm)
Note:
This distance must be increased according to
the increased measurement D if flexible duct is
used.
670
Important!
The unit requires regular maintenance and therefore kitchen furniture panel between cabinets where the unit is lo-
cated must be removable.
Depending on the cupboard depth and selected kitchen furniture panel installation method, the VTR 100/B LITE unit
may have to me shifted forward using wood blocks at the back.
212962 | v02