Configuration Manual

Version Document ID
A
001 Access 4x Configuration manual
46 (56) 2018-07-11
Action
No action
Fast stop
Normal stop
Low speed
Normal speed
High speed
Level
A-alarm
B-alarm
C-alarm
disabel
Delay
0.. sec
No.
Alarm identity number
Editable text
Possible to change the alarm name
Original text
Not possible to change the original text
Som alarms have alarm limits to set
List of all alarm
ID Alarm name
1. Malfunction supply air fan 1
2. Malfunction supply air fan 2
3. Malfunction supply air fan 3
4. Malfunction supply air fan 4
5. Malfunction supply air fan 5
6. Malfunction extract air fan 1
7. Malfunction extract air fan 2
8. Malfunction extract air fan 3
9. Malfunction extract air fan 4
10. Malfunction extract air fan 5
11. Alarm supply air fan 1
12. Alarm supply air fan 2
13. Alarm supply air fan 3
14. Alarm supply air fan 4
15. Alarm supply air fan 5
16. Alarm extract air fan 1
17. Alarm extract air fan 2
18. Alarm extract air fan 3
19. Alarm extract air fan 4
20. Alarm extract air fan 5
21. Warning supply air fan 1
22. Warning supply air fan 2
23. Warning supply air fan 3
24. Warning supply air fan 4
25. Warning supply air fan 5
26. Warning extract air fan 1
27. Warning extract air fan 2
28. Warning extract air fan 3
29. Warning extract air fan 4
30. Warning extract air fan 5
31. External operation supply air fan
32. External operation extract air fan
33. External fan 1 run
34. External fan 2 run
35. Malfunction pump heater
36. Malfunction pump cooler
37. Malfunction pump exchanger
38. Malfunction fire damper
39. Malfunction damper
40. Malfunction external fan 1
41. Malfunction external fan 2
42. Error fire damper position
43. Malfunction pump sequence-A
44. Malfunction pump sequence-B
45. Malfunction pump sequence-C
46. Malfunction pump sequence-D
47. Malfunction pump sequence-E
48. Malfunction pump sequence-F
49. Malfunction pump sequence-G
50. Malfunction pump sequence-H
51. Malfunction pump sequence-I
52. Malfunction pump sequence-J
53. Filter alarm supply air
54. Filter alarm extract air
55. Alarm low air flow
56. Extra freeze protection
57. Defrost protection exchanger alarm
58. Fire alarm
59. Smoke detector alarm
60. External stop
61. External alarm
62. Service stop
63. Electric heater is overheated
64. Warning freeze protection
65. Low efficiency exchanger
66. Defrosting alarm
67. Rotary exchanger alarm
68. Extra alarm 1
69. Extra alarm 2
70. Extra alarm 3
71. Extra alarm 4
72. Extra alarm 5
73. Extra alarm 6
74. Extra alarm 7
75. Extra alarm 8
76. Extra alarm 9
77. Extra alarm 10
78. Internal battery error