IMO(CE) DKEX KTEX

Installation |
9
5.1 Installation example
Fig. 1 DKEX
Fig. 2 KTEX
Installation examples (figure 1 , figure 2) only function as a guideline for installation where dimensioning of suspension
devices must be carried out by the installer and adapted to the prevailing conditions. Fans (3) can be installed using
brackets or suspended mountings (4). If any form of suspension device or bracket is installed on the fans the distance
to moving parts must not be less than 25 mm. Screw or rivet joints must be adapted for the purpose and cleaning of
the fan must be carried out after completed installation. The dashed areas (5) are suitable for installation of ducts and
any suspension devices. Ducts (1) should be connected to fans using collars (2).
141815 | A005