technical documentation manuals 308013008

2
|
Warranty
2.1 Personnel
The fan may only be used by qualified, instructed and trained personnel. The persons must know the relevant safety di-
rectives in order to recognise and to avoid risks. The individual activities and qualifications can be found in Table 1 Qual-
ifications, page 2.
Table 1 Qualifications
Activities
Qualifications
Storage, operation, transport, cleaning, disposal Trained personnel (see following note)
Electrical connection, commissioning, electrical
disconnection
Electrical expert or matching qualification
Installation, disassembly Fitter or matching qualification
Maintenance
Electrical expert or matching
qualification
Fitter or matching
qualification
Repair
Electrical expert or matching
qualification
Fitter or matching
qualification
Smoke extraction fans and EX fans only by agreement with
Systemair.
Note:
The operator is responsible for ensuring that personnel are instructed and have understood the contents of
the operating instructions. If something is unclear, please contact Systemair or its representative.
2.2 Personal protective equipment
Wear protective equipment during all work in the vicinity of the fan.
protective working clothes
protective working shoes
protective working gloves
helmet
goggles
hearing protection
2.3 5 rules of electrical safety
1. Disconnect (disconnection of
the electrical system from
live components at all
terminals)
2. Prevent reactivation
3. Test absence of voltage
4. Ground and short-circuit
5. Cover or restrict adjacent live parts
3 Warranty
For the assertion of warranty claims, the products must be correctly connected and operated, and used in accordance
with the data sheets. Further prerequisites are a completed maintenance plan with no gaps and a commissioning re-
port. Systemair will require these in the case of a warranty claim. The commissioning report is a component of this
document. The maintenance plan must be created by the operator, see section 11.2 Maintenance.
4 Delivery, transport, storage
Safety information
Warning: Risk from rotating fan blades
Prevent access by unauthorised persons by safety personnel or access protection.
Warning: Suspended loads
Wear protective equipment during all work in the vicinity of the fan, details see 2.2 Personal protective equipment,
page 2.
Do not walk under suspended loads.
Make sure that there is nobody under a suspended load.
| 008