WD000157A004

Table Of Contents
TR60 EL3,5
TR60 EL10,4
TR70 HWL, HWH, N
TR70 EL3,5
TR70 EL10,4
TR60 HWL, HWH, N
TR80 HWL, HWH, N
TR80 EL5,2
TR80 EL 12,3
TR80 EL 19,4
TR70 EL14,2
TR60 EL3,5 M0
TR60 HWL, HWH, N M0
TR70 HWL, HWH, N M0
TR70 EL3,5 M0
TR70 EL10,4 M0
TR80 HWL, HWH, N M0
TR80 EL5,2 M0
TR80 EL 12,3 M0
TR35 EL7,1 M0
TR35 EL3,5 M0
TR35 HWL, HWH, N M0
TR60 EL7,1
TR60 EL7,1 M0
Model specific data table 2
Project:
Date:
WD000157
2022-03-25
Rev:
Initials:
HaJa
A004
6
Sheet:
7
Next sheet:Total sheets:
23
0 1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Z = Heater type; HWL = Water coil low power, HWH = Water coil high power
EL4,2 = Electrical heater 4,2kW, N = No heater
Description
AHU Total consumption = without circulation pump consumption
AHU code description
Q=K factor x
Pressure
Air Handling Unit
3
~
400V+N +PE, 50H
z
3
~
400V+N +PE, 50H
z
3
~
400 V +PE, 50H
z
3
~
400V+N +PE, 50H
z
3x16
3x32
B32
B32
B32
3
~
400V+N +PE, 50H
z
B32
3
~
400 V+N +PE, 50H
z
3
~
400V+N +PE, 50H
z
B32
3
~
400V+N +PE, 50H
z
3x50
3,5
3,5
3,5
3,5
3,5
2,1
3,5
3,5
3,5
3,5
7,5
17,8
28
5,1
15,1
5,1
15,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
173
172
*
3
~
400V+N +PE, 50H
z
B323x35 3,5 20,4 2,1
3
~
400V+N +PE, 50H
z
B32 3,2
3,2
5,1 2,0
2,0 148
3
~
400 V +PE, 50H
z
3
~
400V+N +PE, 50H
z
3x13
B32
3
~
400V+N +PE, 50H
z
B32
3,5
3,5
3,5
10,2
15,1
2,0
2,0
2,0 152
3x25
3
~
400V+N +PE, 50H
z
3x40
3xC16
6,2
6,2
6,2
7,5
17,8
4,1
4,1
3
~
400V+N +PE, 50H
z
3
~
400V +PE, 50H
z
3x25
3x20 B32
3
~
400 V+N +PE, 50H
z
3x13 3xC10
3,8
3,8
3,8
5,1
10,2
2,5
2,5
2,5 122
3
~
400V+N +PE, 50H
z
B32 3,5 10,2 2,1
3
~
400V+N +PE, 50H
z
B32 3,2 10,2 2,0
3
~
400V+N +PE, 50H
z
3
~
400V+N +PE, 50H
z
3
~
400V+N +PE, 50H
z
3
~
400V+N +PE, 50H
z
3
~
400V+N +PE, 50H
z
B32
2,1 170
B32
B32
4,1 145
B32
B32
Model type: S-SC20-L-N-ePM1/60-CE-
"
X
"
-
"Y"
-
"
Z
"
-ePM10/60-AC
X = Exhanger damper type; B = Bypass, S = Section defrosting
Y
= Fan wheel type; C1 = Compsite, M0 = Metal wheel
*
Model
*
Power supply
Current consumtion
heater
(
A
)
Current consumtion
fans
(
A/Unit
)
Total power
heater
(
kW
)
Rated power
fans
(
kW/Unit
)
Prefuse AHU
(
A
)
Fan fuse
(
A
)
Heater fuse
(
A
)
Extract air fan
K-factor
(
m
³
/h
)
Supply air fan
K-factor
(
m
³
/h
)
5,2
12,3
19,4
3,5
10,4
3,5
10,4
14,2
3,5
7,1
10,4
5,2
12,3
3,5
7,1
7,1
7,1
171
161
150
120
171
143
3x13
3x13
3x13
3x25
3x25
3x25
3x25
3x16
3x16
3x16
3x32
3x32
3x32
3x35
185
173
172
148
152
122
170
145
171
161
150
120
171
143
185
173
172
148
152
122
170
145
171
161
150
120
171
143
185
173
172
170
171
171
185
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC10
3xC16
3xC16