Installation, Operation and Maintenance instruction 001

1.5 Name plate
1
7
8
9 11
12
2 3 4 5 6
13
10
1. Type designation: Product name, dimension and motor
type. Refer to 1.5.1 Type designation page 2.
2. Current, A
3. Input power, W
4. Frequency, Hz
5. Certifications
6. Scannable code
1
7. Voltage, V
8. IP class, enclosure class
9. Insulation class
10. Serial number: part number/production number/produc-
tion date
11. Nominal fan speed
12. Weight, kg
13. Country of production
Note:
The data on the name plate applies to “standard air” that is
specified in the standard ISO5801.
1.5.1 Type designation
Product name KBR KBR EC KBR/F
Dimension 280 280 280
315 315 315
355 355 355
Motor type D2: 2 pole, 3–phase EC: Electronically commuted
1–phase
D2: 2 pole, 3–phase
D2–4: 2–4 pole, 3–phase EC-K: Electronically com-
muted 1–phase, normal
power
D2–4: 2–4 pole, 3–phase
DV: 4 pole, 3–phase EC-L: Electronically com-
muted 1–phase, high power
DV: 4 pole, 3–phase
E4: 4 pole, 1–phase E4: 4 pole, 1–phase
1.6 Product liability
Systemair is not liable for damages that the product causes
in these conditions:
The product is incorrectly installed, operated or
maintained.
The product is repaired with parts that are not original
spare parts from Systemair.
The product is used together with accessories that are not
original accessories from Systemair.
The product is used without motor protection.
2 Safety
2.1 Safety definitions
Warnings, cautions and notes are used to point out specially
important parts of the manual.
Warning
If you do not obey these instructions,
there is a risk of death or injury.
Caution
If you do not obey these instructions,
there is a risk of damage to the product,
other materials or the adjacent area.
2
1. Use a mobile device to scan the scannable code and go to the Systemair documentation portal for more documentation and document
translations.