DMV HR

5
220-240V ~ 50Hz - Air performance measured according to ISO 5801 a 230V 50Hz, air density 1,2 kg/m
3
.
Product fiche - ErP Directive, Regulations 1253/2014 - 1254/2014
Note: Air flow and thermal efficiency of the HR unit is measured based on pair. That is, not valid for only 1 unit.
a) Mark - Systemair
b) Model - DMV HR 150
c) SEC class - A
c1) SEC warm climates kWh/m2.a -16,2
c2) SEC average climates kWh/m2.a -38,2
c3) SEC cold climates kWh/m2.a -76,4
Energy label - Yes
d) Unit typology - Residential - bidirectional
e) Type of drive - Multi-speed drive
f) Type of Heat Recovery System - Heat recovery
g) Thermal efficiency of heat recovery % 74
h) Maximum flow rate at 0 Pa m
3
/h 60
i) Electric power input (alla Maximum flow rate) W 3,8
j) Sound power level (L
WA
) dBA 38
k) Reference flow rate m
3
/h 41
l) Reference pressure difference Pa 10
m) Specific power input (SPI) W/m
3
/h 0,054
n1) Control factor - 1
n2) Control typology - Manual control (no DCV)
o1) Maximum internal leakage rate % N/A
o2) Maximum external leakage rate % 1%
p1) Internal mixing rate % N/A
p2) External mixing rate % N/A
q) Visual filter warning - N/A
r) Instructions to install regulated grilles - N/A
s) Internet address for pre/disassembly instructions - www.systemair.com
t) Airflow sensitivity to pressure variations % N/A
u) Indoor/outdoor air tightness m
3
/h 60
v1) AEC - Annual electricity consumption - warm
climates
kWh 0,7
v2) AEC - Annual electricity consumption - average
climates
kWh 0,7
v3) AEC - Annual electricity consumption - cold
climates
kWh 0,7
w1) AHS - Annual heating saved - warm climates kWh 18,1
w2) AHS - Annual heating saved - average climates kWh 40
w3) AHS - Annual heating saved - cold climates kWh 78,2
Air-flow at different speed m
3
/h 60/40/20
Power consumption at different speed W 3,8/2,3/1,4
Sound pressure at 3 m at different speed
1
dB(A) 26/18/10
Thermal efficiency
2
% 70/74,3/82
Ambient temperature max °C -20°C ÷ +50°C
Degree of protection IP - X4
Marking/Mark -
1 Sound pressure level at 3m in free field, for comparative purposes only.
2 Measured at the independent laboratory HLK of the University of Stuttgart (Germany).
I II
2016 1254/2014
ENERGIA · ʫʻʫˀʧʰ˔ · ȵɁȵɆȳȵȻȰ · ENERGIJA · ENERGY · ENERGIE ͽEZ'/
A+
A
B
C
D
E
F
G
264762 DMV HR 150
38
dB
60 m
3
/h