The unit should operate continuously, and only stopped for maintenance or service. When heat exchange is not useful (for example in
mid-seasons when indoor and outdoor temperatures are similar), or when heat exchange is not recommended (for example with the
option “summer free cooling”), it is recommended to set the unit in “extract-only” or “intake-only” mode and NOT to switch it off.
INTRODUCTION
QuantumHRisasinglealternateflowdecentralized(singlepoint)residentialheatrecoveryunit,alsocalled«push&pull»unit,designedtoensure
adequateventilationinenclosedenvironmentswithoutenergylosses.
Itisrecommendedthattwounitsareinstalledinpair:whenoneunitispulling,theotherispushing.Pairofunitscanbeinstalledinthesameroomor
indifferentrooms(i.e.livingroomandbedroom).Theunitissuitableforinstallationonanoutsidewall.
• Innerventilationunitmaterial:highquality,impactandUV-resistantABScolourRAL9010.
• Designfrontcoverremovableforcleaningwithouttheuseoftools.
• Easymaintenanceinstallationplate,foreasyaccesstotheheatexchangerfrominsidetheroom.
• Anti-dustlter,easilyremovableforwashingbytheuserwithouttools.
• Regenerativehoneycombsceramicheatexchanger.
• Externalgrilleinhighquality,impactandUV-resistantABScolourRAL9010.
• Highefciencyaerodynamicfanwith“winglet”bladestooptimisequietnessandefciency.
• SinglephaseECreversibleBrushlessmotorwithintegralthermalprotection.
• Motormountedonhighqualityballbearings.
• Theunitisdoubleinsulated:noearthconnectionisrequired.
• Tricklespeedselectable.
• Boostmode.
• Free-cooling(Bypass)mode.
• IPX4degreeofprotection.
TECHNICAL SPECIFICATIONS
EN
Readthismanualcarefullybeforeusingtheproductandkeepitinasafeplaceforreference.
Thisproductwasconstructeduptostandardandincompliancewithregulationsrelatingtoelectricalequipmentandmust
beinstalledbytechnicallyqualifiedpersonnel.
Themanufacturerassumesnoresponsibilityfordamagetopersonsorpropertyresultingfromfailuretoobservethe
regulations contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
•Thedeviceshouldnotbeusedforapplicationsotherthanthosespeciedinthismanual.
•Afterremovingtheproductfromitspackaging,verifyitscondition.Incaseofdoubt,contactaqualiedtechnician.Do
notleavepackagingwithinthereachofsmallchildrenorpeoplewithdisabilities.
•Donottouchtheappliancewithwetordamphands/feet.
•Thisappliancecanbeusedbychildrenagedfrom8yearsandaboveandpersonswithreducedphysical,sensoryor
mentalcapabilitiesorlackofexperienceandknowledgeiftheyhavebeengivensupervisionorinstructionconcerning
useoftheapplianceinasafewayandunderstandthehazardsinvolved.Childrenshallnotplaywiththeappliance.
Cleaningandusermaintenanceshallnotbemadebychildrenwithoutsupervision.
•Donotusetheproductinthepresenceofinammablevapours,suchasalcohol,insecticides,gasoline,etc.
•Ifanyabnormalitiesinoperationaredetected,disconnectthedevicefromthemainssupplyandcontactaqualied
technicianimmediately.Useoriginalsparepartsonlyforrepairs.
•Theelectricalsystemtowhichthedeviceisconnectedmustcomplywithregulations.
•Beforeconnectingtheproducttothepowersupplyorthepoweroutlet,ensurethat:
-thedataplate(voltageandfrequency)correspondtothoseoftheelectricalmains
-theelectricalpowersupply/socketisadequateformaximumdevicepower.Ifnot,contactaqualiedtechnician.
•Thedeviceshouldnotbeusedasanactivatorforwaterheaters,stoves,etc.,norshoulditdischargeintohotair/fume
ventductsderivingfromanytypeofcombustionunit.Itmustexpelairoutsideviaitsownspecialduct.
•Operatingtemperature:-20°Cupto+50°C.
•Thedeviceisdesignedtoextractcleanaironly,i.e.withoutgrease,soot,chemicalorcorrosiveagents,orammable
orexplosivemixtures.
•Donotleavethedeviceexposedtoatmosphericagents(rain,sun,snow,etc.).
•Donotimmersethedeviceoritspartsinwaterorotherliquids.
•Turnoffthemainswitchwheneveramalfunctionisdetectedorwhencleaning.
•Forinstallationanomnipolarswitchshouldbeincorporatedinthexedwiring,inaccordancewiththewiringregulations,to
provideafulldisconnectionunderovervoltagecategoryIIIconditions(contactopeningdistanceequaltoorgreaterthan
3mm).
•Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer,itsserviceagentorsimilarlyqualiedpersonsin
ordertoavoidahazard.
•Donotobstructthefanorexhaustgrilletoensureoptimumairpassage.
•Ensureadequateairreturn/dischargeinto/fromtheroomincompliancewithexistingregulationsinordertoensure
proper device operation.
•Iftheenvironmentinwhichtheproductisinstalledalsohousesafuel-operatingdevice(waterheater,methanestove
etc.,thatisnota“sealedchamber”type),itisessentialtoensureadequateairintake,toensuregoodcombustionand
properequipmentoperation.
•InstalltheproductsothattheimpellerisnotaccessiblefromtheairoutletsideasveriedbycontactwiththeTestFinger
(testprobe“B”ofthenormEN61032)incompliancewiththecurrentsafetyregulations.