OPTIMA-R-FM Air Flow Measurement Device Handbook
/12 | OPTIMA-R-FM Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Dimensions & Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Ordering Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
/12 | OPTIMA-R-FM Description The air flow measurement device OPTIMA-R-FM is intended for continuous reading of the air flow volume in the circular-shaped ventilation ducts. The air flow volume is interpreted and transmited by the analog signal or by the bus communication.
/12 | OPTIMA-R-FM Product Parts OPTIMA-R-FM-...-BM OPTIMA-R-FM-...
/12 | OPTIMA-R-FM Dimensions & Weights OPTIMA-R-...-FM- SA 170 45 DN-3 DN-3 57 70 OPTIMA-R-...-FM-BM 45 170 45 260 45 260 (mm) DN (mm) OPTIMA-R-FM-...
/12 | OPTIMA-R-FM Ordering Codes Nominal diameter DN 80 100 125 140 160 180 200 225 250 280 315 355 400 500 630 OEM, Communication type SA Siemens, Analog BM Belimo, Analog, Modbus, BACnet Example of the Ordering Code OPTIMA-R-FM-160-BM Air flow measurement device with circular shape of nominal dimension 160, analog, modbus or BACnet communication, OEM Belimo.
/12 | OPTIMA-R-FM Installation OPTIMA-R-FM-...
/12 | OPTIMA-R-FM Measurement The air flow transmitter measures the flow velocity dependent dynamic pressure on the measurement probe. The air flow volume is interpreted by the transmitter in the form of analog signal U in the 0 V ... 10 V or the 2 V ... 10 V mode from the analog output. The air flow volume q can be calculated using this analog voltage value and the nominal air flow volume Vnom of the measurement device. The Vnom values are in the table of dimensions.
/12 | OPTIMA-R-FM Electrical Connections Type of Measurement Transmitter BM Supply voltage: DC/AC 24V Terminals: 2,5 mm² Power rating: 2 VA Type of Measurement Transmitter SA Supply voltage: AC 24V Cable (6 wires): 0,75 mm² Power rating: 1 VA Legend G wire 1-1 red phase AC 24 V G0 wire 2-1 black common conductor U wire 9-1 pink flow measurement signal DC 0 V ...
/12 | OPTIMA-R-FM Transport, Storage and Operation
/12 | OPTIMA-R-FM Supplement Any deviations from the technical specifications contained herein and the terms should be discussed with the manufacturer. We reserve the right to make any changes to the product without prior notice, provided that these changes do not affect the quality of the product and the required parameters. Current information on all products is available on design.systemair.com.