Original instructions SWX CS SE ... 8 FR ... 30 EN ... 12 NO ... 16 DE ... 20 ES ... 25 IT NL ... 40 PL ... 45 RU ... 49 ...
SWX CS SWX CS A min 150 E ØI G B F C H D [mm] SWX CS12 SWX CS22 A 585 740 B 535 660 C 455 455 D 705 725 Electrical installation 230V~ Terminal box 0,85 m cable 2 E R3/4" R3/4" F 250 270 G 330 420 H 410 505 ØI 10 10
SWX CS Accessories Type SWXCDFT1 SWXCDFT2 SWXCS12 SWXCS22 HxWxD [mm] 515x425x5 620x565x5 SWXCDFT Controls SWX CS Type RSK-nr (SE) NRF-nr (NO) SWXRT35 HxWxD [mm] 175x150x100 SWXRT35 Water regulation SWX CS Type SD20* TVV20* TVV25* RSK-nr (SE) 672 70 37 672 70 35 672 70 36 Water regulation NRF-nr (NO) 85 021 57 85 021 47 85 021 48 + TVV20/25 SD20 3
SWX CS Wiring diagrams SWX CS Internal SWX CE/CS M ~ 10 11 BK BU WT RD L N SWX CS Control by thermostat only SWXCE/CS -12, -22 SWXCE/CS -12, -22 M ~ SD20* SD20* TVV20/25* TVV20/25* 10 11 BK BU WT RD L N *) Note! Only for mounting outside corrosive environment.
SWX CS SWX CS Typ Heat output*1 [kW] SWXCS12 20 SWXCS22 37 Airflow Airflow [m³/h] 2160 4300 [m³/s] 0,6 1,2 Sound level*2 [dB(A)] 59 69 ∆t*1,3 [°C] 27 25 Air throw [m] 7 10 Water volume*4 [l] 1,5 2,4 Voltage Amperage Weight [V] 230V~ 230V~ [A] 0,5 1,35 [kg] 31 47 *1) Applicable at water temperature 80/60 °C, air temperature, in +15 °C. *2) Conditions: Distance to the unit 5 metres. *3) ∆t = temperature rise of passing air at maximum heat output. *4) Water volume inside battery.
SWX CS Output charts water SWX CS Incoming / outgoing water temperature 90/70 °C Air temp. in = +5 °C Type Airflow Output [m³/h] [kW] 28,9 54,1 SWXCS12 2160 SWXCS22 4300 Air temp. out [°C] 44,5 42,2 Air temp. in = +15 °C Water flow Pressure drop [l/s] [kPa] 0,36 16,5 0,66 19,2 Output [kW] 24,6 46,0 Air temp.
SWX CS 7
GB SWX CS Installation and operating instructions General Instructions Read these instructions carefully prior to installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid should the product be used in the manner intended and in accordance with the instructions. Application SWX is a range of fan heaters suitable for environments with strict demands on materials and safety.
SWX CS GB Fitting the wall brackets 1. Remove the eight screws indicated by the arrows in picture A. A 3. The fan heater may be mounted with the connection pipes facing left or right, as seen from the front. In rooms with high ceilings, the fan heater should be installed in a low position, but not so low that it intrudes on the working space. Make sure that the wall is able to support the weight of the fan heater. C 2. Install the brackets with the holes toward the fan motor, as shown in picture B.
GB SWX CS Connection of heating coil The installation must be carried out by an authorized installer. By turning the fan heater, pipe connections are possible on both sides. Connect the water supply pipe to the lower pipe on the heater and connect the outlet pipe to the upper pipe, as shown by the arrows in picture E. All models use R3/4” connections. Note! Be careful while connecting the pipes to prevent pipe damage and water leakage.
SWX CS Cleaning The interval between each cleaning depends on the environment the fan heater is used in. Dust on the fan protective grille and on the water coil’s aluminum fins impedes the airflow and reduces its heat exchanging performance. The water coil must therefore be kept clean. The fan cooling flanges also need to be kept clean, to obtain the lowest possible motor operating temperature.
Tel: +46 31 336 86 00 mailbox@frico.se www.frico.net For latest updated information and information about your local contact: www.frico.