EDM SYSHP MINI SPLIT 06 16
Table Of Contents
- CONTENTS
- CONTENTS
- 1.1 System Schematic
- 1.2 System Configurations
- 2 Unit Capacities
- 2.1 Outdoor unit
- 3 Nomenclature
- 3.1 Outdoor unit
- 3.2 Hydronic box
- 4 System Design and Unit Selection
- 4.1 Selection procedure
- 4.2 M thermal Leaving Water Temperature (LWT) Selection
- 5 Typical Applications
- 5.1 Space Heating Only
- 5.2 Space Heating and Domestic Hot Water
- 5.3 Space Heating, Space Cooling and Domestic Hot Water
- 5.4 Space Heating and Domestic Hot Water (Bivalent)
- 5.4.2 Auxiliary heat source provides space heating and domestic hot water
- 5.5 Space Heating Through Floor Heating Loops and Radiators
- 5.6 Space Heating, Space Cooling and Domestic Hot Water Compatible with Solar Water Heater
- Part 2 Engineering Data
- 1.1 Outdoor Unit
- 1.2 Hydronic Box
- 2 Dimensions and Center of Gravity
- 2.1 Outdoor Unit
- 2.2 Hydronic Box
- 3.1 Outdoor Unit
- 4 Wiring Diagrams
- 4.1 Outdoor Unit
- 4.2 Hydronic Box
- 5 Capactiy Tables
- 5.2 Cooling Capacity Tables (Test standard:EN14511)
- 7 Hydronic Performance
- 8.1 Overall
- 8.2 Octave Band Levels
- 9.1 Outdoor Unit
- 1.1 Notes for Installers Boxes
- 2 Installation
- 2.1 Acceptance and Unpacking
- 2.3 Outdoor unit
- 1
- 1.1
- 1.2
- 1.3
- 1.4
- 1.5
- 2.4 Hydronic box
- 3 Refrigerant Pipework
- 3.1 Permitted Piping Length and Level Difference
- 3.3 Procedure and Principles
- 3.4 Storing Copper Piping
- 3.8 Pipe Flushing
- 3.9 Gastightness Test
- 4 Water Pipework
- 4.1 Water Circuit Checks
- 4.2 Water volume and sizing expansion vessels
- 4.3 Water Circuit Connection
- 4.4 Water Circuit Anti-freeze Protection
- 5.1 General
- 5.4 Wiring Overview
- 8.1 Introduction
- 8.2 Menu Structure
- 8.11 HOLIDAY AWAY SETTING Menu
- 8.14 TEST RUN
- 8.15 SPECIAL FUNCTION
- 8.16 AUTO RESTART
- 8.20 HMI ADDRESS SET
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 10.1 Install APP
- 10.2 Sign in
- 10.3 Add device and login to home Wi-Fi
- 10.4 Wired Controller Setting
- 10.4.2 Finishing up
- 11 USB Function Guidelines
- 11.1 Parameters setting transfer between wired controllers
- 11.2 Convenient program upgrade for unit
- 12 Climate Related Curves
- 13 Error Code Table
- Part 1 General Information
- Part 2 Engineering Data
- Part 3
- Installation and Field Settings
- 1 Air-to-Water HP Split System
- 2 Unit Capacities
- 3 Nomenclature
- 4 System Design and Unit Selection
- 5 Typical Applications
- 1 Specifications
- 3 Piping Diagrams
- 4 Wiring Diagrams
- 5 Capactiy Tables
- 6 Operating Limits
- 7 Hydronic Performance
- 8 Sound Levels
- 9 Accessories
- 1 Preface to Part 3
- 3 Refrigerant Pipework
- 4 Water Pipework
- 6 DIP Switch Settings
- 7 Internal Circulation Pump
- 8 User Interface Field Settings
- 9 Operation parameter
- 10 Network Configuration Guidelines
- 11 USB Function Guidelines
- 12 Climate Related Curves
- 13 Error Code Table
115
13 Error Code Table
Table 3-13.1: Error code table
Table connued on next page …
Error code Content
C7 Transducer module temperature too high protecon
E0 Water ow failure (E8 appears 3 mes)
E1 Phase sequence error (for 3 phase models)
E2 Communicaon error between the main control board of hydraulic module and user interface
E3 Backup electric heater exchanger water outlet temperature sensor T1 error
E4 Domesc hot water tank temperature sensor T5 error
E5 Air side heat exchanger refrigerant outlet temperature sensor T3 error
E6 Outdoor ambient temperature sensor T4 error
E7 Balance tank sensor Tbt1 error
E8 Water ow failure within 3 mes
E9 Sucon pipe temperature sensor Th error
EA Discharge pipe temperature sensor Tp error
Eb Solar board sensor Tsolar error
Ec Balance tank sensor Tbt2 error
Ed Water side heat exchanger water inlet temperature sensor Twin error
EE. Hydronic box EEPROM error
F1 DC generatrix voltage is too low
H0 Communicaon error between outdoor unit main control chip and hydronic box main control chip
H1 Communicaon error between outdoor unit main control chip and inverter driver chip
H2 Water side heat exchanger refrigerant outlet (liquid pipe) temperature sensor T2 error
H3 Water side heat exchanger refrigerant inlet (gas pipe) temperature sensor T2B error
H4 Inverter module protecon (L0/L1 appear 3 mes in one hour)
H5 Room temperature sensor Ta error
H6 DC fan error
H7 Abnormal main circuit voltage
H8 Pressure sensor error
H9 Zone 2 water outlet temperature sensor Tw2 error
HA Water side heat exchanger water outlet temperature sensor error
Hb PP protecon appears three mes in a row and Twout<7℃
H.F. Invert module EEPROM error
HH H6 appears 10 mes in 120min
HP Low pressure protecon (pressure < 0.6MPa for 3 mes in one hour)
P0 Low pressure protecon
P1 High pressure protecon
P3 Compressor current protecon
P4 Discharge temperature sensor Tp protecon
P5 High temperature dierence between water side heat exchanger water inlet and water outlet temperatures protecon
P6 Inverter module protecon
L0 Inverter module protecon
L1 DC bus low voltage protecon
L2 DC bus high voltage protecon