The largest level dierence between indoor unit and outdoor unit should not exceed 20m.
3.2 Pipe Size and Connect method
3 Refrigerant Pipework
3.1 Permied Piping Length and Level Dierence
The piping length and level dierence limitaons that apply are summarized in Table 3-3.1. Before installaon, it is necessary to
check if the piping length and height dierence are meeng the requirements.
Figure 3-3.1: Connect method
Table 3-3.1: Permied Piping Length and Level Dierence
Table 3-3.2: Refrigerant pipe connecon
Outdoor Unit
max. dierence in height
Indoor Unit
Models 4-16kW
Max. piping length
30m
Max. dierence in height
20m
Models 4/6kW 8/10kW 12/14/16kW
Pipe connect
Pipe size
Gas side (Φ15.9); Liquid side
(Φ6.35);
Gas side (Φ15.9); Liquid side
(Φ9.52);
Gas side (Φ15.9); Liquid side (Φ9.52);
Connect method
Flare Flare Flare