8.11 HOLIDAY AWAY SETTING Menu
MENU > FOR SERVICEMAN > HOLIDAY AWAY SETTING
The HOLIDAY AWAY SETTING menu sengs are used to set the outlet water
temperature to prevent water pipes freezing when away from home in cold
weather seasons. In HOLIDAY AWAY SETTING the following parameters should
be set.
T1S_H.A._H sets the heat pump’s leaving water set temperature for space
heang mode when in holiday away mode.
T5S_H.A._DHW sets the heat pump’s leaving water set temperature for DHW
mode when in holiday away mode.
8.12 SERVICE CALL Menu
MENU > FOR SERVICEMAN > SERVICE CALL
In SERVICE CALL the following parameters can be set.
PHONE NO. and MOBILE NO. can be used to set aer-sales service contact numbers. If set, these numbers are displayed to users
in MENU > FOR SERVICEMAN > SERVICE CALL
Use ▼ ▲ to adjust the numerical values. The maximum length of the phone numbers is 14 digits.
The black rectangle found between 0 and 9 when scrolling up and down using is
converted to a blank space when
the phone numbers are displayed to users in MENU > FOR SERVICEMAN > SERVICE
CALL and can be used for phone
numbers less than 14 digits in length.
8.13 RESTORE FACTORY SETTINGS
MENU > FOR SERVICEMAN > RESTORE FACTORY SETTINGS
RESTORE FACTORY SETTINGS is used to restore all the parameters set in the user interface to their factory defaults.
On selecng YES, the process of restoring all sengs to their factory defaults begins and progress is displayed as a percentage.
Figure 3-8.29: HOLIDAY AWAY SETTING menu
Figure 3-8.30: SERVICE CALL menu
Figure 3-8.31: RESTORE FACTORY SETTINGS screens