IMO AW 1000D EC SILEO DE,EN

Operating instructions
3.2 Nominal data
Motor M3G150-NA
Phase 3~
Nominal voltage / VAC 400
Nominal voltage
range / VAC
380 .. 480
Frequency / Hz 50/60
Method of obtaining
data
ml
Speed / min
-1
960
Power consumption /W 2580
Current draw / A 4.0
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
70
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to ErP Directive
Actual Req. 2015
01 Overall efficiency
η
es
/
%
54.4 36.2
02 Measurement category A
03 Efficiency category Static
04 Efficiency grade N 58.2 40
05 Variable speed drive Yes
06 Year of manufacture
The year of manufacture is specified on the
product's rating label.
08 Type W3G990-DZ02-09
09 Power consumptio
n
P
ed
/ kW 2.54
09 Air flow
q
v /
m³/h
24185
09 Pressur
e
increas
e
tota
l
p
sf
/
Pa
194
10 Speedn/ min
-1
965
11 Specific ratio
*
1.00
12 Recycling/disposal
Information on recycling and disposal is
provided in the operating instructions.
13 Maintenance
Information on installation, operation and
maintenance is provided in the operating
instructions.
14 Additional components
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.
*
Specific ratio = 1 + pfs / 100 000 Pa
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller
combination in a standardized measurement setup.
3.4 Technical description
Weight 61.2 kg
Fan size 990 mm
Rotor surface Painted black
Electronics housing
material
Die-cast aluminum, painted black
Blade material Sheet aluminum insert, sprayed with PP
plastic
Fan housing material Sheet steel, pre-galvanized and coated
with black plastic (RAL 9005)
Guard grille material Steel, coated with black plastic (RAL
9005)
Number of blades 5
Blade pitch -5°
Airflow direction "A"
Direction of rotation Counterclockwise, viewed toward rotor
Degree of protection IP55
Insulation class "F"
Moisture (F) /
Environmental (H)
protection class
F4-1
Installation position Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
drainage holes
On rotor side
Mode S1
Motor bearing Ball bearing
Technical features - RS-485 MODBUS-RTU
- PFC, passive
- Control input 0-10 VDC / PWM
- Thermal overload protection for
electronics/motor
- Alarm relay
- Integrated PID controller
- Input for sensor 0-10 V or 4-20 mA
- Output for slave 0-10 V
- Motor current limitation
- Soft start
- Line undervoltage / phase failure
detection
- Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
- External 24 V input (parameter setting)
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Electrical hookup Via terminal box
Motor protection Reverse polarity and locked-rotor
protection
Protection class I (with customer connection of protective
earth)
Conformity with
standards
EN 61800-5-1; CE
Approval C22.2 No.77 + CAN/CSA-E60730-1;
EAC; UL 1004-7 + 60730