B. Display Menu Keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Callout Key Function
6 Status Shows operational information.
7 Quick Menu Allows access to programming
parameters for initial set-up instructions
and many detailed application
instructions.
8 Main Menu Allows access to all programming
parameters.
9 Alarm Log Displays a list of current warnings, the
last ten alarms, and the maintenance
log.
Table 5.2 Legend to Figure 5.1, Display Menu Keys
C. Navigation Keys and Indicator Lights (LEDs)
Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local (hand) operation. There are
also three adjustable frequency drive status indicator lights
in this area.
Callout Key Function
10 Back Reverts to the previous step or list in the
menu structure.
11 Cancel Cancels the last change or command as
long as the display mode has not
changed.
12 Info Press for a definition of the function being
displayed.
13 Navigation
keys
Press to move between items in the
menu.
14 OK Press to access parameter groups or to
enable a choice.
Table 5.3 Legend to Figure 5.1, Navigation Keys
Callout Indicator Light Function
15 ON Green The ON light activates when the
adjustable frequency drive
receives power from AC line
voltage, a DC bus terminal, or
an external 24 V supply.
16 WARN Yellow When warning conditions are
met, the yellow WARN light
comes on and text appears in
the display area identifying the
problem.
17 ALARM Red A fault condition causes the red
alarm light to flash and an alarm
text is displayed.
Table 5.4 Legend to Figure 5.1, Indicator Lights (LEDs)
D. Operation Keys and Reset
Operation keys are located at the bottom of the LCP.
Callout Key Function
18 Hand On Starts the adjustable frequency drive in
local control.
An external stop signal by control
input or serial communication
overrides the local hand on
19 Off Stops the motor but does not remove
power to the adjustable frequency drive.
20 Auto On Puts the system in remote operational
mode.
Responds to an external start
command by control terminals or
serial communication
21 Reset Resets the adjustable frequency drive
manually after a fault has been cleared.
Table 5.5 Legend to Figure 5.1, Operation Keys and Reset
NOTICE!
The display contrast can be adjusted by pressing [Status]
and [
]/[
] keys.
Commissioning Instruction Manual
24 Danfoss A/S © Rev. 11/06/2014 All rights reserved. MG11AK22