SysCoil Comfort Fan coil units Models VC, VN, HC, HN / 10 to 80 0.61 to 12.90kW 0.51 to 9.
SYSCOIL COMFORT Quality, efficiency and reliability Vertical console units with cabinet, VC type Support feet supplied as optional VC vertical console units are designed for use in three different types of installation : Q as a wall hung console in areas where a skirting board prevents the use of a floor mounted console ; Q as a floor console with optional front air intake FA (most frequently located below a large window) ; Q as a floor console with support feet and bottom air intake They feature a moder
2 SYSCOIL COMFORT New range of fan coil units SYSCOIL COMFORT: "Innovation for an optimum comfort" Design features Easy to install, improvement in sound levels and performances, SysLogic electronic control, etc., are the key developments carried on our fan coil units. The SYSCOIL COMFORT II fan coil unit range is issued from that development striving to meet customers’ wishes and advices.
SYSCOIL COMFORT New range of fan coil units SYSCOIL COMFORT: "Innovation for an optimum comfort" Fan and motor assembly Controls The units are fitted with a fan-motor assembly of which the fan is composed of double inlet forward curved centrifugal wheel(s) dynamically balanced and specially designed for an optimal air flow and a low noise level..
4 SYSCOIL COMFORT Models designation SCC10 . C . SYS . 2P . 500W . EC . S1S3S4 . L . G3 . SL . 3W . FTG + MRC 1 2 REP.
SYSCOIL COMFORT Product Codes AC Motor SCC10 SCC20 SCC30 SCC40 SCC50 SCC60 SCC70 SCC80 Code Description Code Description Code Description Code Description Code Description Code Description Code Description Code Description 2 pipes VN / HN VC / HC 4 pipes VN / HN VC / HC 2 pipes VN / HN VC / HC 4 pipes VN / HN VC / HC 374264 SCC10.2P.L.G2 374272 SCC20.2P.L.G2 374280 SCC30.2P.L.G2 374288 SCC40.2P.L.G2 374296 SCC50.2P.L.G2 374304 SCC60.2P.L.G2 374312 SCC70.2P.L.G2 374320 SCC80.2P.L.
6 SYSCOIL COMFORT SYSCOIL COMFORT - Mounting Accessories Wall mounting with cabinet - SYSCOIL COMFORT VC STD standard version for wall mounting (no support feet supplied). FT support feet for floor mounting. FTG air intake grille between feet. FA-REMOV front air intake grille (no support feet supplied). BACK-MA air intake arrangement with manual damper (back or/and front intake). FLOOR-MA air intake arrangement with manual damper (floor or/and front intake).
SYSCOIL COMFORT SYSCOIL COMFORT - Mounting Accessories Wall mounting without cabinet - SYSCOIL COMFORT VN STD standard version for wall mounting (no support feet supplied). FT support feet for floor mounting. FA front air intake. BACK-MA air intake arrangement with manual damper (back or/and front intake). FLOOR-MA air intake arrangement with manual damper (floor or/and front intake).
8 SYSCOIL COMFORT SYSCOIL COMFORT - Mounting Accessories Ceiling mounting with cabinet - SYSCOIL COMFORT HC STD FA-REMOV FLOOR-MA FT FTG STD standard ceiling mounted version with rear air intake (no inlet grille). bottom air intake grille. air intake arrangement with manual damper. support feet. air intake grille between feet.
SYSCOIL COMFORT SYSCOIL COMFORT - Mounting Accessories Ceiling mounting without cabinet - SYSCOIL COMFORT HN STD FLOOR-MA FA standard ceiling mounted version with rear air intake (no inlet grille). air intake arrangement with manual damper. bottom air intake.
10 SYSCOIL COMFORT Available Options 2-way control valve - 2-pipes system - 230 Volt thermal actuator Models SCC10/ SCC60 SCC70/ SCC80 1 valve, 2-way type - For 2-pipes system on cooling or heating coil Thermal actuator Valve 230 V - 50/60 Hz T max T max Id (A) In (A) P (VA) KV Ø amb fluid 1.6 1/2" 50 °C 110 °C 0.6 0.013 3.0 2.5 3/4" 50 °C 110 °C 0.6 0.013 3.0 2-way control valve - 4-pipes system - 230 Volt thermal actuator Models SCC10/ SCC60 SCC70/ SCC80 2 valves.
SYSCOIL COMFORT Main Controls (Optional) TRM-FA (supplied loose) Electromechanical remote control TAE20 (supplied loose) Electronic remote thermostat VC VC VN VN HC HC HN HN Q Wall mounted remote thermostat to control valves and fan. Q Adjustable Q Suitable for 4-pipes (with cooling and heating valves), 2-pipes/2-wires dead zone electronic thermostat with summer/winter automatic changeover.
12 SYSCOIL COMFORT Main Controls (Optional) SysLogic communicating electronic control (supplied fitted) SysLogic communicating electronic control System networking Optional supervisor connected to the optional MB2 card Max 1 wihtin a zone MB2 + - G + - G Main Board Zone HMI Max 1 wihtin a zone CTRL Mode VC VN HC HN 3 4 5 GND SIG 12 V Main Board CTRL 3 4 5 GND SIG Max number of main boards connected : 15 Q SysLogic controller can be configured in 2-pipes heating only or cooling
SYSCOIL COMFORT Technical Data SYSCOIL COMFORT with AC motor SCC10 SCC20 SCC30 SCC40 V1 V3 V5 V1 V3 V5 V1 V3 V5 V1 V3 V5 Capacites - 2 pipes Total cooling capacity KW 0.66 1.00 1.45 0.61 0.96 1.38 0.95 1.88 2.37 1.14 2.28 3.02 Sensible capacity KW 0.48 0.77 1.05 0.43 0.70 1.02 0.78 1.44 1.80 0.83 1.66 2.23 Water flow l/h 114 172 250 105 165 238 164 324 408 196 393 520 Water pressure drop (3) kPa 9.17 19.50 39.10 1.42 2.69 4.65 5.79 17.60 26.
14 SYSCOIL COMFORT Technical Data SYSCOIL COMFORT with AC motor SCC50 SCC60 SCC70 SCC80 V1 V3 V5 V1 V3 V5 V1 V3 V5 V1 V3 V5 Capacites - 2 pipes Total cooling capacity KW 1.71 3.16 4.64 2.57 4.33 5.53 3.24 5.84 6.91 4.40 5.78 7.72 Sensible capacity KW 1.24 2.23 3.27 1.81 3.14 4.25 2.26 4.11 4.85 3.24 4.35 5.98 Water flow l/h 295 544 799 443 746 953 558 1 006 1 190 758 996 1 330 Water pressure drop (3) kPa 7.45 22.80 47.10 12.60 33.90 54.40 4.
SYSCOIL COMFORT Technical Data SYSCOIL COMFORT with EC motor SCC10 SCC20 SCC30 SCC40 V1 V3 V5 V1 V3 V5 V1 V3 V5 V1 V3 V5 Capacites - 2 pipes Total cooling capacity KW 0.59 1.16 1.96 0.61 1.31 2.12 0.82 1.95 2.93 1.34 2.93 4.19 Sensible capacity KW 0.48 1.00 1.76 0.47 1.06 1.72 0.61 1.53 2.28 0.95 2.10 3.00 Water flow l/h 102 200 338 105 226 365 141 336 505 231 505 722 Water pressure drop (3) kPa 7.51 25.70 69.50 1.42 4.29 9.25 4.62 18.80 38.
16 SYSCOIL COMFORT Technical Data SYSCOIL COMFORT with EC motor SCC50 SCC60 SCC70 SCC80 V1 V3 V5 V1 V3 V5 V1 V3 V5 V1 V3 V5 Capacites - 2 pipes Total cooling capacity KW 1.34 3.57 4.98 1.98 4.45 5.24 2.55 5.56 6.55 4.59 6.13 8.36 Sensible capacity KW 1.05 2.70 3.70 1.35 3.51 4.02 1.91 4.10 4.96 3.32 4.51 6.28 Water flow l/h 231 615 858 341 767 903 439 958 1 128 791 Water pressure drop (3) kPa 4.86 28.70 53.90 7.75 35.80 49.00 2.72 12.60 17.50 11.
SYSCOIL COMFORT Technical Data Electrical heater with electric heating Models BE1 BE2 heating capacity Minimum air flow heating capacity Minimum air flow W m /h W m3/h SCC10 500 108 / / SCC20 500 98 / / SCC30 500 145 1000 (500 + 500) 206 SCC40 1 250 276 / / 3 SCC50 1 250 250 SCC60 1 250 300 SCC70 1 250 350 SCC80 1 250 380 2500 (1250 + 1250) 2500 (1250 + 1250) 2500 (1250 + 1250) 2500 (1250 + 1250) 484 475 522 812 Operating range with EC motor : Voltage setpoint
SYSCOIL COMFORT Water Pressure Drops SYSCOIL COMFORT with AC motor 2-pipe system - Cooling Mode 70 60 Pressure drop (kPa) SCC60 50 SCC50 SCC10 40 30 SCC80 SCC30 SCC40 20 SCC70 10 0 SCC20 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 Water flow (L/H) 2-pipe system - Heating Mode 70 SCC60 60 Pressure drop (kPa) 18 50 SCC80 40 SCC50 SCC10 30 SCC30 SCC40 SCC70 20 10 0 SCC20 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 17
SYSCOIL COMFORT Water Pressure Drops SYSCOIL COMFORT with AC motor 4-pipe system - Cooling Mode 70 Pressure drop (kPa) 60 50 SCC80 SCC60 40 SCC40 30 SCC10 SCC70 20 SCC30 10 0 SCC50 SCC20 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Water flow (L/H) 4-pipe system - Heating Mode 90 SCC70 80 Pressure drop (kPa) 70 60 SCC80 50 40 SCC60 30 SCC40 20 SCC50 10 0 SCC30 SCC20 SCC10 0 100 200 300 400 500 Water flow (L/H) 600 700 800 900 19
SYSCOIL COMFORT Water Pressure Drops SYSCOIL COMFORT with EC motor 2-pipe system - Cooling Mode 80 70 Pressure drop (kPa) 60 SCC50 SCC10 SCC40 50 SCC60 SCC30 40 SCC80 30 20 SCC70 10 0 SCC20 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 Water flow (L/H) 2-pipe system - Heating Mode 60 SCC60 SCC40 50 SCC10 Pressure drop (kPa) 20 SCC80 SCC50 40 SCC30 30 20 SCC70 10 0 SCC20 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700
SYSCOIL COMFORT Water Pressure Drops SYSCOIL COMFORT with EC motor 2-pipe system - Cooling Mode 80 70 SCC80 Pressure drop (kPa) 60 SCC10 50 SCC40 40 SCC60 30 SCC30 SCC50 20 SCC70 10 0 SCC20 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 Water flow (L/H) 4-pipe system - Heating Mode 100 90 SCC80 Pressure drop (kPa) 80 SCC70 70 60 50 40 SCC60 30 SCC40 20 SCC50 10 0 SCC10 SCC20 0 100 SCC30 200 300 400 500 600 700 Water flow (L/H) 800 900 1000 1100
SYSCOIL COMFORT Dimensions SYSCOIL COMFORT VC / HC G G D C 100 F 192 E H Discharge Return Ground level B A 225 192 144 98 SCC10 SCC20 SCC30 SCC40 SCC50 SCC60 SCC70 SCC80 A 240 240 240 240 240 240 240 240 B 428 428 613 798 983 1 168 983 1 168 C D 360 360 360 360 360 360 360 360 189 189 374 559 744 929 744 929 E 415.5 415.5 415.5 415.5 415.5 415.
SYSCOIL COMFORT Dimensions SYSCOIL COMFORT VN WITH DRAIN GUARD G G D C 100 F 192 E H Discharge Return B Ground level A 16 I 15 SCC10 SCC20 SCC30 SCC40 SCC50 SCC60 SCC70 SCC80 A 240 240 240 240 240 240 240 240 15 I B 428 428 613 798 983 1 168 983 1 168 C D 360 360 360 360 360 360 360 360 189 189 374 559 744 929 744 929 E 415.5 415.5 415.5 415.5 415.5 415.5 519 519 F 61 61 61 61 61 61 61 86 15 15 220 123 12 184 21 50 16 G 692.5 692.
SYSCOIL COMFORT Dimensions - Water connections 1 Discharge 1 Return A C 2 Discharge Return A C B D 1 2 Inlet 2 pipes 2 3 Outlet or or B D 4 Inlet Outlet / / 2 4 pipes Ground level Ground level Right - 4 pipes 1 2 1 F B H D 2 Left - 4 pipes D H B 100 A C 1 C A 1 4 4 Return E A C G F Return B H D A E C B H D G F 4 4 3 3 2 2 1 1 A E C G C A E 100 Discharge G 3 3 Ground level Ground level A B C D E F G H SCC10 295 100 337 71 277 139 40
SYSCOIL COMFORT Notes 25
26 SYSCOIL COMFORT Notes
Systemair AC SAS · route de Verneuil, 27570 Tillières-sur- Avre · Tél. 02 32 60 61 00 · Fax 02 32 32 55 13 november 2021 Systemair · EDM SCC 01-S-2GB/10.21 - Supersedes : EDM SCC 01-S-1GB/12.18 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. www.systemair.