Installation, Operation and Maintenance instruction AxZent Thermo Centrifugal fan AC AxZent Thermo Centrifugal fan EC
Table of content 1 Introduction .......................................................... 1 1.1 Product description ...................................... 1 1.2 Intended use .............................................. 1 1.3 Document description................................... 1 1.4 Product overview......................................... 1 1.5 Name plate ................................................ 2 1.5.1 Type designation ............................. 2 1.6 Product liability...................
1 Introduction 1.1 Product description The product is intended for installation in duct systems. The product can also be installed with free suction or free discharge together with a protection grille. This product is a thermo centrifugal fan with a radial fan impeller. The motor is located outside the airstream. The casing has flanges that agree with Eurovent 1/2. The product is not applicable for transportation of air that contains explosive, flammable or aggressive media.
1.5 Name plate 1 2 1.6 3 4 5 6 Product liability Systemair is not liable for damages that the product causes in these conditions: 7 • The product is incorrectly installed, operated or maintained. 8 • The product is repaired with parts that are not original spare parts from Systemair. 9 • The product is used together with accessories that are not original accessories from Systemair. 10 11 12 13 14 1. Type designation: Product name, dimension and motor type. Refer to 1.5.
2 Safety • Read this manual and make sure that you understand the instructions before you do work on the product. 2.1 Safety definitions • Obey local conditions and laws. Warnings, cautions and notes are used to point out specially important parts of the manual. • Keep this manual at the location of the product. Warning • Do not install or operate the product if it is defective. If you do not obey these instructions, there is a risk of death or injury.
3 Transportation and storage Warning Make sure that the product does not become damaged or wet during transportation. A damaged or wet product can cause fire or electric shock. 4 Installation 4.1 To do before the installation of the product • Make sure that you have the necessary installation accessories: – Refer to 13 Accessory overview page 17 for an overview of the accessories. • Before you move the product to the installation location, examine the packaging for damages.
4.2 1 2 To install the product Put the product in the correct position: a. Install the product with accessories that decrease vibrations in the product and the duct system. a. Install the product with the motor up or to the sides. If you install the product vertically, install mounting rings (A) against the ceiling and use flexible connections (B): B 135° 135° 45° 45° Caution A Do not install the product with the motor down. Dirt can collect in the fan housing. b.
3 If you install the product near a duct bend, do these steps to prevent vibrations, unwanted noise and decreased air pressure: a. Measure the distance (A) between the product and the duct bend. b. Make sure that the distance (A) is a minimum of 2.5 x the diameter (B) of the duct system. For circular ducts, (B) is the nominal diameter. For rectangular ducts, (B) is the hydraulic diameter. A 5 Electrical connection 5.
5.6 To install motor protection for AC motors 6 Commissioning Caution • If the product has an built in motor protection, reset by disconnecting the product from power for 60 seconds. • If strong vibrations occur during commissioning, immediately increase or decrease the fan speed until the vibrations are decreased. Continuous strong vibrations can cause damage to components.
7 Operation Caution EC motors must be set to ON/OFF via the control input. To stop the product via mains supply decreases the life time of the motor. Systemair recommends to install external speed controller for easy access to control the input signal. 7.1 To start a product with an EC motor 1 Make sure that the 0–10 V signal is set to “0” with the speed controller. 2 Set the installed safety switch in the ON position and wait 5 seconds.
8 Maintenance Warning Set the installed safety switch in the OFF position before you do the maintenance unless the instructions tell you differently. Make sure that the safety switch is not accidentally set in the ON position. 8.1 Maintenance schedule The intervals are calculated from continuous operation of the product. Maintenance task Usual operation conditions Each 6 months Each year Unusual operation conditions.
9 Troubleshooting Note: If you cannot find a solution to your problem in this section, speak to Systemair technical support. Problem Cause Solution The fan impeller is not correctly balanced. Speak to Systemair technical support. There is dirt on the fan impeller. Clean the fan impeller carefully. Refer to 8.2 To clean the product page 9. The fan impeller has damages or deformations because the transported air contains aggressive media. Speak to Systemair technical support.
Problem Cause Solution The fan impeller does not turn in the correct direction. Make sure that the electrical connection is correctly done. A phase loss occurred. If the motor is a 3-phase motor, make sure that no phase is missing. Note: This is not applicable for EC motors. The motor is overheated. Thermal contacts, PTC or resistors are released. • Do a check of the motor cooling impeller. • If it is possible, measure the resistance to do a check of the motor winding.
10 Disposal The product follows the WEEE directive. This symbol on the product or the packaging of the product shows that this product is not domestic waste. The product must be recycled at an approved disposal location for electrical and electronic equipment. 11 Warranty For warranty claims, send a written maintenance plan and the commissioning report to Systemair. The warranty is only applicable for these conditions: • The product is correctly installed and operated. • Motor protection is used.
12 Technical data 12.1 Technical data overview Max. temperature of transported air, °C 120 Sound pressure, dB Refer to the data sheet in the online catalogue at www.systemair.com. IP class Voltage, current, frequency, enclosure class, weight Motor data 12.2 Refer to the name plate. Refer to 1.5 Name plate page 2 for more information. Refer to the motor name plate or the technical documentation from the motor manufacturer.
AxZent 400 AxZent 450 AxZent 500 AxZent 560 AxZent 630 EC 635 660 746 795 899 E4 653.8 679.2 744.2 815 898 DV 637.5 662.9 727.7 N/A N/A D2 722.5 748.4 N/A N/A N/A D4 N/A N/A N/A 808.4 898 Motor type H, mm 12.3 Wiring diagrams The wires in the motor cables have these colours: Wire Colour +10V Red 0...10V/PWM Yellow GND Blue 12.3.
EC-Basic EC-Basic 1/IN Vac 230V AC 2/IN Vac +10V 4/Out 0...10V 5/GND GND MTV–1/10 MTV 1/010 1/IN Vac 230V AC 2/IN Vac +10V 4/Out+ 0...10V 5/Out- GND S-5EC/FRQ MTP 10 10V +10V GND 0...10V A GND EC-Vent EC-Vent IN/RPM optional IN/10V OUT/PWN GND TACH +10V PWM 0...
12.3.2 Wiring diagrams for ON/OFF controls for EC motors CO2RT-R(-D) CO2RT-R-D Supply +10V Neutral 0...10V Common GND 24V AC Relay NO Relay NC Din1 IR24–P IR24-P 24V +10V Neutral 0...
13 Accessory overview 1 2 3 4 5 6 4 7 8 9 10 1. 2. 3. 4. 5. SG: Protection grille ESD-F: Inlet cone RSA: Silencer EVH: Flexible connection MPR: Mounting ring for vertical installation through a roof 6. 7. 8. 9. 10. WSD: Weather protection roof LRK: Airflow shutter GFL: Counter flange MFA: Mounting foot FSD: Spring vibration damper for horizontal installation Note: For more information about accessories, refer to www.systemair.com or speak to Systemair technical support.
14 EU Declaration of Conformity We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Thermo fans — AxZent Type/Model AxZent 400–630 AxZent 400–630EC Identification Serial numbers dating from 2021 and onwards fulfils all relevant provisions of the Machinery directive 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General principles for design Riskassessment and risk reductio
15 UKCA Declaration of Conformity We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Thermo fans — AxZent Type/Model AxZent 400–630 AxZent 400–630EC Identification Serial numbers dating from 2021 and onwards fulfils all relevant provisions of the Supply of Machinery (Safety) Regulations 2008 DIN EN ISO 12100:2013 Safety of machinery - General principles for design Riskassessment
last page Systemair GmbH Seehöfer Str. 45 97944 Boxberg Germany Tel.: +49 (0)7930/9272-0 Fax: +49 (0)7930/9273-92 info@systemair.de www.systemair.de © Copyright Systemair AB All rights reserved EOE Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications.