Circular duct fan prioAir, prioAir Silent Installation and Operating Instructions Document in original language | · 006 GB
© Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications.
Contents 1 General information .........................................1 1.1 Notice symbols ......................................1 1.1.1 Instruction symbols.....................1 2 Important safety information .............................1 2.1 Personnel .............................................1 2.2 Personal protective equipment..................2 2.3 5 rules of electrical safety ........................2 3 Warranty .......................................................
General information | 1 General information 1.1 Notice symbols Danger Caution Direct hazard Failure to comply with this warning will lead directly to death or to serious injury. Hazard with a low risk Failure to comply with this warning may lead to moderate injuries. Warning Important Potential hazard Failure to comply with this warning may lead to death or serious injury. Hazard with risk of damage to objects Failure to comply with this warning will lead to damage to objects.
2 | Warranty Qualifications cont'd Installation, disassembly Fitter or matching qualification Maintenance Electrical expert or matching qualification Fitter or matching qualification Electrical expert or matching qualification Fitter or matching qualification Repair Smoke extraction fans and EX fans only by agreement with Systemair. Note: The operator is responsible for ensuring that personnel are instructed and have understood the contents of the operating instructions.
Delivery, transport, storage | Warning When opening the transport packaging, there is a risk of damage from sharp edges, nails, staples, splinters etc. ♦ Unpack the fan carefully. ♦ Check the fan for obvious transport damage. ♦ Only remove the packaging shortly before assembly. ♦ Wear protective equipment during all work in the vicinity of the fan, details see 2.2 Personal protective equipment, page 2. 4.3 4.3.
4 | Description 5 Description prioAir equipped with an EC motor The fans are driven by EC motors. These motors are delivered with a pre-wired potentiometer (0–10 V) that allows you to easily find the required working point of the fan. All motors are suitable for 50/60 Hz. The input voltage for singlephase units can vary between 200 and 277 V. All models have one potential-free terminal for error message.
Description | 5.1 Fan data • Max. temperature of transported air, max. ambient temperature, sound pressure –> see data sheet, available in our online catalogue. • Voltage, current, enclosure class, weight –> see name plate 5.2 Intended use • The fans are intended for installation in ventilation systems. They can be installed both in duct systems and also with free suction via a suction-side contact protection grille. Free discharge via a contact protection grille is also possible.
6 | Name plate and type key 6 Name plate and type key 1 2 4 3 1 Type designation 3 Input power/fan impeller speed 2 Voltage/frequency/current 4 Certifications Table 4 Type key prio 200 EC -L - Normal motor version -L Large motor version Motor type EC Electronically commutated/1 phased E2 2 poled/voltage controllable/1 phased Size Fan type prioAir Circular duct fan prioAir Silent Circular duct fan with Silencer | 006
Accessories | 7 Accessories Note: For details of the accessories, please check our online catalog or contact Systemair.
8 | Installation 8 Installation 8.1 Safety information General safety information ♦ Installation may only be carried out by adequately qualified persons, details see Table 1 Qualifications, page 1. ♦ Wear protective equipment during all work in the vicinity of the fan, details see 2.2 Personal protective equipment, page 2. ♦ Abide by the system-related conditions and requirements of the system manufacturer or plant constructor.
Electrical connection | 8.3 Installation variations The installation is possible in any mounting position. Installation with mounting bracket Note: The mounting bracket is available in our accessory range. ♦ Mount the mounting bracket on the fan, see adjacent image. 9 Electrical connection 9.1 Safety information Warning: Danger from electrical voltage! ♦ Observe the 5 rules of electrical safety, see 2.3 5 rules of electrical safety, page 2. ♦ Prevent the ingress of water into the connection box.
10 | Electrical connection 9.3.1 Wiring diagram prioAir E2 Color Function/pin assignment Black L Blue N Neutral conductor Green/Yellow PE Protective conductor Power supply 230 V AC, 50...60 Hz 9.3.1.1 Wiring diagram prioAir EC The fans are delivered with a pre-wired potentiometer (0–10 V) Client side Max. speed Adjustable speed 10V –> n = max 1V –> n = min <1V –> 0 Adjustable speed through PWM 1...
Commissioning | 9.5 Residual current circuit breaker All-current-sensitive residual current circuit breakers are required for use in alternating-current systems with 50/60 Hz, in combination with electronic devices such as EC motors, frequency converters or uninterruptible power supplies (UPS). 9.6 Protecting the motor Note: In fans equipped with an EC motor, there is no additional motor protection needed. The motor protection is integrated in the electronics of the motor.
12 | Operation 10.3 Tests ♦ Before switching the fan on, check for externally visible damage and ensure that the protective equipment functions properly. AC motor 1. Switch the fan on. 2. Checks: ♦ Direction of rotation/conveyance. The direction of rotation always applies looking at the impeller. • The direction of rotation is best observed just before the fan stops. ♦ Smooth running (any vibrations and noise) EC motor When the mains are switched on, the motor starts an initialization (a few seconds).
Troubleshooting/maintenance/repair | 12.2 Troubleshooting Table 5 Troubleshooting Problem Fan does not run smoothly Air output of fan too low Grinding sounds when starting or operating the fan Thermal contacts/ resistors have triggered Fan does not reach nominal speed Motor does not rotate Electronics/motor overheated Possible causes Remedy Soiling on the impeller Clean carefully Material decomposition on the impeller due to aggressive material conveyed.
14 | Cleaning 12.3 Maintenance Warranty claims can only be made if maintenance work is carried out correctly and written evidence thereof is provided. We recommend regular maintenance intervals to ensure continuous fan operation. These maintenance intervals are specified in the “Activities” table below. In addition, the operator must carry out follow-up activities such as cleaning, replacing defective components or other corrective measures.
Deinstallation/dismantling | 13.2 Procedure Important Keeping the fan clean extends its service life. ♦ Install a filter monitor. ♦ Do not use steel brushes or sharp-edged objects. ♦ Do not use a high-pressure cleaner (steam jet cleaner) under any circumstances. ♦ Do not bend the fan blades when cleaning. ♦ When cleaning the impeller, pay attention to balance weights that have been positioned ♦ Keep the airways of the fan clear and clean them if necessary with a brush.
16 | Commissioning Report 16 Commissioning Report Warranty claims can only be made if commissioning work is carried out correctly and written evidence thereof is provided. Fan Description: Article no.: Manufacturing order no.: Installer Company: Contact person: Company address: Tel. no.: Email: Operator (Place of installation) Company: Contact person: Company address: Tel. no.
EU Declaration of conformity | Current L2 [A]: Air volume [m3/s]: Current L3 [A]: Differential pressure [Pa]*: *For single-phase fans, fill in line “Current L1 [A]” *Δ- Pressure between suction-side and discharge of the fan If an air flow measurement is not possible, this value can be calculated using the following formula: = X Flow speed [m/s] Duct cross-section [m²] Grille measurement acc.
Tel.: +49 (0)7930/9272-0 Fax: +49 (0)7930/9273-92 info@systemair.de www.systemair.de Circular duct fan · Installation and Operating Instructions · · en_GB · 2018-09-27 · 006 Systemair GmbH Seehöfer Str.