Electrical board
Electric equipment is built in compliance with CE stand-
ards. Easy accessible in front of the unit - through an ac-
cess panel xed with screws - the equipment is complete
with:
Door lock main isolating switch
Compressor contactors and fuses
Compressor overload protection (optional)
Automatic circuit breaker switches (optional)
Phase sequence control
Clamps for remote start/stop switch
Clamps for remote summer/winter switch
Clamps for external ow switches (both exchangers)
Clamps for remote double set-point
Clamps for external interlock
Clamps for remote general alarm
Connection clamps to remote keyboard (optional)
Clamps for evaporator/condenser pump relay control
(optional)
Clamps for boiler relay control (optional)
Clamps for dynamic set-point compensation (4-20 mA,
0-1 V, 0-5 V, 0-10 V)
Clamps for outdoor air temperature probe (accessory)
Electronic control SC655
Soft-starter (optional)
Power factor correction capacitors (optional)
0-10 V clamps for condensing control (optional)
Control
A new optimized control is supplied on all the units with a
simple user interface (possibility to customize keys func-
tions and to set menus visibility).
In addition to standard features as water temperature
control (with possibility to choose LWT/EWT probe), the
control can also manage following functions:
Dynamic set point (4-20 mA, 0-1V, 0-5V, 0-10V)
Double set point
OAT compensation
Boiler integration
Condensing control
Auto adaptative function to reduce the water content of
the plant
Advanced pump management (both primary circuit and
source side)
Remote keyboard (accessory) with possibility to con-
nect (up to 100 m distance) without any serial interface
Safety
Each unit is equipped with following electrical/refrigerant
/hydraulic safety devices:
Door lock main isolating switch
Phase monitor control
High pressure switch with manual reset
Discharge safety valve
Low pressure switch with automatic / manual reset
Anti-freeze probe (leaving water temperature)
Differential pressure switch (source / plant side)
Standards
WQL/WQH/WQRC are built in compliance with following
standards:
Machinery Directive: 2006/42/EC
Electromagnetic Compatibility Directive: 2014/30/UE
Pressure Equipment Directive: 2014/68/UE
Ecodesign Directive: 2009/125/EC
And following harmonized European standards:
Safety of machinery - Basic concepts, general principles
for design: UNI EN ISO 12100-1 / 2
Safety of machinery - Safety Distances To Prevent Haz-
ard Zones Being Reached By Upper And Lower Limbs:
EN ISO 13857
Safety of machinery - Electrical equipment of machines:
EN 6020 4-1
Low-voltage switchgear and controlgear assemblies:
EN 60439-1
Electromagnetic compatibility (EMC) - Immunity for in-
dustrial environments: IEC EN 61000-6-2
Electromagnetic compatibility (EMC) - Emission stand-
ard for residential, commercial and light-industrial envi-
ronments: IEC EN 61000-6-3
Refrigerating systems and heat pumps. Safety and en-
vironmental requirements: EN 378-1 / 2
Metallic products - Types of inspection documents: EN
10204
Ecodesign: REG. 813/2013, REG.2015/1095,
REG. 2016/2281
Factory installed options
ModBus protocol kit for BMS
Compressor soft starter
Power factor correction capacitors
Electronic expansion valve
Compressor overload protection
Automatic circuit breaker
Condensing control kit
Additional heating device wiring kit
Mechanical gauges kit
Compressor jacket
On board hydrokit (1P/2P/both exchangers/SP-HP)
Desuperheater
Field installed accessories
Remote ON-OFF
Remote keyboard panel
Sequencer up to 4 units
Condensing control kit
Outdoor air sensor for climatic compensation
Additional heating device wiring kit
Compressor jacket
Flow switch
Pressure switch
Victaulic to threaded pipe connection
Spring type anti-vibration mounts
Water lter