415004 Topvex TR Installation Instructions

Topvex TR800, TR1300, TR1800, TR4000 Installation instructions
Systemair Inc.
1
1 Warning
The following admonitions will be presented in the different sections of the document.
Danger
Make sure that the Main power supply to the unit is disconnected before performing any
maintenance or electrical work!
All electrical connections must be carried out by an authorized installer and in accordance with local
rules and regulations.
Warning
The door handles are only intended to be used during the installation. Handles must be removed
before the unit is put into operation to ensure the required level of safety for the unit.
• The unit must be duct connected or in some other way provided with protection so that it is not
possible to come in contact with the fans through the duct connections.
The unit is heavy. Be careful during transport and mounting. Risk of injury through pinching. Use
protective clothing.
Beware of sharp edges during mounting and maintenance. Make sure that a proper lifting device is
used. Use protective clothing.
The units electrical connection to main power supply must be preceded by an all pole circuit breaker
with a minimum 0.1” (3 mm) gap.
Important
If the unit is installed in a cold place make sure that all joints are covered with insulation, and tape
well
Duct connections/duct ends should be covered during storage and installation
Do not connect tumble dryers to the ventilation system
Take care not to damage the water coil when connecting water pipes to connectors. Use a spanner
to tighten the connection.
2 Product Information
2.1 General
This installation manual concerns air handling unit Topvex TR manufactured by Systemair Inc.
Topvex TR include the following model options:
Model: TR800, TR1300, TR 1800, TR4000
Heating coil: EL (Electric), HW (Water coil) or None.
Airow control: CAV (Constant Air Volume), VAV (Variable Air Volume = Constant duct pressure control)
Water heating coil can be ordered as an accessory for units without re-heater.
This manual consists of basic information and recommendations concerning the design, installation, start-
up and operation, to ensure a proper fail-free operation of the unit.
The key to proper and safe operating of the unit is to read this manual thoroughly, use the unit according to
given guidelines and follow all safety requirements.
1 Warnings
The following admonitions will be presented in the different sections of the document.
Danger
Make sure that the Mains supply to the unit is disconnected before performing any maintenance or
electrical work!
All electrical connections must be carried out in accordance with local rules and regulations.
Warning
In order for the unit to be considered safely installed the doors if equipped with handles have to be
locked with a key to prevent unauthorized or accidental opening
The unit must be duct connected or in some other way provided with protection so that it is not
possible to come in contact with the fans through the duct connections
The unit is heavy. Be careful during transport and mounting. Risk of injury through pinching. Use
protective clothing.
Beware of sharp edges during mounting and maintenance. Make sure that a proper lifting device is
used. Use protective clothing.
Caution
If the unit is installed in a cold place make sure that all joints are covered with insulation, and tape well
Duct connections/duct ends should be covered during storage and installation
Do not connect tumble dryers to the ventilation system
Take care not to damage the water battery when connecting water pipes to connectors. Use a
spanner to tighten the connection.
Topvex FR03, FR06, FR08, and FR11
Installation instructions
206638
1
Systemair AB
1 Warnings
The following admonitions will be presented in the different sections of the document.
Danger
Make sure that the Mains supply to the unit is disconnected before performing any maintenance or
electrical work!
All electrical connections must be carried out in accordance with local rules and regulations.
Warning
In order for the unit to be considered safely installed the doors if equipped with handles have to be
locked with a key to prevent unauthorized or accidental opening
The unit must be duct connected or in some other way provided with protection so that it is not
possible to come in contact with the fans through the duct connections
The unit is heavy. Be careful during transport and mounting. Risk of injury through pinching. Use
protective clothing.
Beware of sharp edges during mounting and maintenance. Make sure that a proper lifting device is
used. Use protective clothing.
Caution
If the unit is installed in a cold place make sure that all joints are covered with insulation, and tape well
Duct connections/duct ends should be covered during storage and installation
Do not connect tumble dryers to the ventilation system
Take care not to damage the water battery when connecting water pipes to connectors. Use a
spanner to tighten the connection.
Topvex FR03, FR06, FR08, and FR11
Installation instructions
206638
1
Systemair AB