SAVE VTR 150K INSTALLATIONV01 20210316

6
| Installation
5.1 Where/how to install
Fig. 3 SAVE VTR 150/K in a kitchen environment
The SAVE VTR 150/K is to be mounted above a stove.
A
Minimum distance
between cabinets (mm)
600
B
SAVE VTR 150/K unit
width (mm)
598
C,
Electrical
stove
Minimum distance
between stove surface
and cooker hood (mm)
450
(Recommen-
ded 500)
C, Gas
stove
Minimum distance
between stove surface
and cooker hood (mm)
650
5.2 Wall preparation for mounting bracket
The unit should be installed in such a way that there is no vibration noise
coming from the wall on which the unit is installed.
5.3 Outdoor Air Intake Location Recommendation
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
5.4 Access to Power supply
The SAVE VTR 150/K is supplied with approximately 1,5 m cable and plug for 230V, single phase earthed connection.
Make sure a power outlet is reachable by the plug.
6 Installation
Important
The device may only be installed by qualified, instructed and trained personnel. The persons must know the
relevant safety directives in order to recognise and to avoid risks.
254494 | v01