© Copyright Systemair UAB All rights reserved E&OE Systemair UAB reserves the rights to change their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications. Systemair is not liable or bound by the warranty if these instructions are not adhered to during installation or service.
Contents 1 2 3 4 5 6 Overview ......................................................1 1.1 General Description ................................1 1.2 Warranty ..............................................1 1.3 Type label.............................................1 Important Safety Information .............................1 2.1 Intended Use.........................................1 2.2 Admonitions .........................................2 Technical Data ..............................................
Overview | 1 Overview 1.1 General Description Read the instructions carefully and in its entirety. For description of advanced settings and installation of accessories see Service and Accessories Installation manual. All documents can be found in our online catalogue at www.systemair.com. 1.2 Warranty For the assertion of warranty claims, the products must be correctly connected and operated, and used in accordance with the data sheets.
2 | Technical Data • The system should operate continuously, and only be stopped for maintenance/service. • Do not connect tumble dryers to the ventilation system. • Make sure that filters are mounted before starting the unit. 2.
Technical Data | 3.1 Dimensions and Weight Fig. 2 Dimensions of left hand unit The unit weight is 46 kg. 3.2 Connections Left and Right models Position Description R Right hand model (Supply air connection is situated on the right hand side of the unit viewed from the front) L Left hand model (Supply air connection panel is situated on the left hand side of the unit viewed from the front) Duct connections: Ø 125 mm Fig.
4 | Delivery, Transport, Storage Symbol 3.3 3.3.1 Description Symbol Description Supply air Outdoor air Exhaust air Extract air Symbol Description Cooker hood air Installation recommendation regarding condensation Condensation inside of the unit When the unit is installed in a cold attic (close to outdoor temperature) the unit should run continuously.
Prerequisites for Installation | Checking delivery • Check the packaging and the air handling unit for transport damage. Any findings should be noted on the cargo manifest. • Check completeness of the delivery. Verify that all ordered equipment is delivered before starting the installation. Any discrepancies from the ordered equipment must be reported to the supplier of Systemair products.
6 | Prerequisites for Installation D When flexible duct is used, distance between the unit and cooker hood is decided by the installer (minimum 100 mm).
Installation | Make sure a power outlet is reachable by the plug. 6 Installation Important • The device may only be installed by qualified, instructed and trained personnel. The persons must know the relevant safety directives in order to recognise and to avoid risks. Verify that all ordered equipment are delivered before starting the installation. Any discrepancies from the ordered equipment must be reported to the supplier of Systemair products.
8 | Installation Fig. 5 Sticker dimensions 6.1 Wall preparation for mounting bracket 1. Prepare the surface where the unit is to be mounted. Make sure that the surface is flat, vertical and that it supports the weight of the unit. Perform the installation in accordance with local rules and regulations. Fig. 6 Surface preparation. C — concrete/bricks, W — wood block, G — gypsum, M — mineral wool If the wall is from a thick concrete or bricks, no special preparation is needed (figure 6, pos.
Installation | Make sure there is a power socket is located nearby the unit, preferably above it. It must be earthed. SAVE VTR 150/ B power cable length is 1 – 1,5 m and it comes out from the top left side in right version units and from the right top side in left version units. Choose power socket location accordingly. Fig. 7 Installation of mounting bracket without or with wooden blocks 2. Screw the mounting bracket (pos. 1) with the anti-vibration pad (pos. 2) to the wall (figure 7, pos. A).
10 | Installation The cooker hood is attached directly to the bottom of the unit. This option can be used when the whole unit with a cooker hood will be shifted forward using wood blocks to be alighted with the cupboards or when the cupboard size matches the unit and no adjustments are needed. This way the unit can be simply mounted directly on the wall with already attached cooker hood. Important Follow instructions delivered with the cooker hood how to prepare it before installation. Fig.
Installation | 6.3 Installation with 251-10/B cooker hood Product name and number • 251-10/B White Cookerhood – 96698 • 251-10/B Stainless Cookerhood – 96699 There are two options to mount the cooker hood: • The cooker hood is attached directly to the bottom of the unit. This option can be used when the whole unit with a cooker hood will be shifted forward using wood blocks to be alighted with the cupboards or when the cupboard size matches the unit and no adjustments are needed.
12 | Installation Fig. 11 Placing the unit on the mounting bracket (the cooker hood is not shown) 3. Pull the cooker hood power supply and control cables to the top since the mounted SAVE VTR 150/B unit will block access to the back. 4. Once all cooker hood cables at the back are led to the top, lift the unit and hang it on the mounting bracket. Warning Beware of sharp edges during mounting and maintenance. Use protective gloves.
Installation | 6.4.1 Installation between or in a cupboard without a base with a cooker hood attached directly to the unit 1. Remove the cooker hood filter to access holes at the top of the cooker hood from inside. Insert included screws (figure 12, pos. 2) into the cooker hood holes, place included plastic spacers on the each protruding screw to prevent over-tightening (figure 12, pos. 3). 2. Place a circular insulation on the cooker hood connector to prevent air leaking (figure 12, pos. 4). 3.
14 | Installation 6.4.2 Installation between or in a cupboard without a base using brackets When the cooker hood cannot be attached directly to the unit, use included brackets. Flexible duct is needed to connect the cooker hood with the SAVE VTR 150/B unit when using this type of installation. 1. Fig. 14 Installation using brackets Mark out and fasten screws so that they protrude a few millimetres from both cupboard sides (figure 14, pos. A).
Installation | 2. Attach the brackets as far into the cooker hood as possible. Insert the cooker hood up into the hole in the base of the cupboard. Pull out (figure 16, pos. A) and use screws to fasten the brackets to the sides of the cupboard (figure 16, pos. B). Tighten the brackets in the cooker hood. Fig. 16 Installation using brackets 6.5 Wiring and configuration Connect control signal wires from the cooker hood to UI2 and 24 V on the external connection board (figure 17).
16 | Installation Adjust bolts if shifting distance is less than 25 mm or use wood blocks in case the required distance is greater. Fig. 19 Installation of bolts 1. Install four M6 bolts into threaded inserts on the unit and lock bolts with hex nuts (figure 19). Bolts protrusion can be adjusted later. A cross screwdriver and a 10 mm spanner are needed. They are not included in the package. Fig. 20 Installation of hooks and mounting of the kitchen furniture panel 2.
Installation | Fig. 21 Installation of bolts and brackets 1. Install four M6 bolts into threaded inserts in brackets and lock bolts with hex nuts (figure 21). Bolts protrusion can be adjusted later. A cross screwdriver and a 10 mm spanner are needed. They are not included in the package. Brackets are adjustable vertically (figure 21, A) and horizontally (figure 21, B). Align the brackets with the underside of the unit. Fully tighten screws after adjusting the brackets. Fig.
18 | Electrical connections 6.6.3 Fitting the kitchen furniture panel as a door Another suggested option is to use hinges instead of brackets and install the kitchen furniture panel as a hinged cupboard door. Hinges or other needed parts for this installation method are not included in the package. Fig. 23 Kitchen furniture panel as a door 7 Electrical connections The SAVE VTR 150/B is wired internally from factory.
Electrical connections | Fig.
20 | Before Starting the System Fig. 26 External connection box and board Position Description 1 Connection to the main circuit board 2 Connection for external control panel (HMI) or Internet access module (IAM) 3 Modbus RS485 connection AI6–7 Freely configurable Analog input. None/Input type selection in HMI. DO1–4 Freely configurable digital output.
Concluding Routines | Note: If the SAVE Light control panel is used, the start-up wizard is skipped and the factory settings are used. Select language, set the time and choose airflow control type. Select revolutions per minute as the type of airflow control only if these values are included with the device. Set speed of supply and extract air fans for each level. When finished, review your settings. It is possible to go back to previous menus and make modifications. Choose heating type or none.
22 | Disposal and recycling 11 Disposal and recycling This product is compliant with the European WEEE Directive and related national waste legislation. When disposing the unit, follow your local rules and regulations. This product packing materials are recyclable and can be reused. Do not dispose in household waste.
EU Declaration of Conformity | 12 EU Declaration of Conformity Manufacturer EN 60529 Systemair UAB Linų st. 101 LT–20174 Ukmergė, LITHUANIA Office: +370 340 60165 Fax: +370 340 60166 www.systemair.com The manufacturer hereby confirms that SAVE VTR 150/B comply with all applicable requirements in the following directives and regulations.