Operating Instructions

KPB
Check control of the product components
Make the shaft(s) turning by hand and make sure they turn freely.
Clean the product before installation.
Check that motor(s) turn on the right direction.
Maintenance
Check always the product before putting it at work, and after having
remained at stand still for a long period of time.
Check all bearings once a month, and if necessary, apply the suitable
grease.
Revise the belt(s) tightened once a month.
Revise the fan impeller and housing once a month.
Bearings
Bearings of the different components on this product are already
lubricated, and therefore the must not be lubricated before the first
installation of the product. Under normal working conditions, bearings
must be lubricated after 20.000 working hours or 2 years, wathever is
first, and for lubrication, it must be used Lithium based grease with the
specifications Type K3K-30 DIN 51825 and consistency NLGI-3. Bearings
must not be removed from their housing for lubrication purposes.
ATTENTION
All products equipped with electric and moving rotors with IP protection
degree (CEI Standard) must be kept out of people reaching, and in case
of need protected by the necessary elements. Systemair manufactures a
wide range of components for protection. Please consult our catalogue.
Installation of the product, must be done according to the rules applying
in each country.
4