Connection of di󰀨erent actuators
When connecting thermal actuators, DO4 is used for heating actuators
and DO5 for cooling actuators. If the installation is a 2-pipe installation
and the change-over function is used, the actuator should be connected
to DO4.
When connecting 3-point actuators, DO4 is used for increase signal and
DO5 for decrease signal, even when the change-over function is used.
10 L 230 V AC Line Power supply
11 - Not connected
12 N 230 V AC Neutral Power supply (internally con-
nected to terminal 13)
13 N Fan-coil common /
230 V AC Neutral
Common fan-coil connec-
tor (internally connected to
terminal 12)
20 DO1 Fan-coil output 1
for fan control
Relay, 230 V AC*, 3 A
21 DO2 Fan-coil output 2
for fan control
Relay, 230 V AC*, 3 A
22 DO3 Fan-coil output 3
for fan control
Relay, 230 V AC*, 3 A
30 - Not connected
31 DO4 Digital output 4 for
heating/cooling
or opening with
3-point actuator
Digital output. 230 V AC, max
300 mA. Max 2 A during 20
ms.
32 CDO45 Common DO4 & 5 Common connection for
digital outputs 4 and 5
33 DO5 Digital output 5 for
cooling or closing
with 3-point actua-
tor.
Digital output. 230 V AC, max
300 mA. Max 2 A during
20 ms.
40 DI Digital input Potential-free window contact
or occupancy contact. Con-
gurable for NO/NC.
41 Agnd Analogue ground
42 AI Analogue input External PT1000 instead of
the internal NTC
43 UI Universal input Change-over input. Potential-
free switch (congurable for
NO/NC) or PT1000.
44 Agnd Analogue ground
50 Agnd Analogue ground
51 - Analogue out A0I EC fan
52 - Not connected
53 A RS485 communication A
54 B RS485 communication B
*The sum of the current through DO1-DO3 is protected by a fuse
Low Voltage Directive (LVD) standards / EMC emissions &
immunity standards
This product conforms to the EMC and LVD requirements in the
European harmonised standards EN 60730-1:2000 and EN 60730-2-
9:2002 and carries the CE mark.
RoHS
This product conforms to the Directive 2011/65/EU of the European
Parliament and of the Council.
Contact
Frico AB, Industrivägen 41, 433 61 Sävedalen, Sweden
Tel: +46 31 336 86 00, Fax: +46 31 26 28 60
www.frico.net, mailbox@frico.se
Figure 5: Connection diagram with water heater
Figure 6: internal placement
Figure 8: External placement
ECGT1
Modbus
EXOline
BACnet
M
Modbus
EXOline
BACnet
M
B
AO1
0 V Y
EC fan