126183 MANUAL 772 10
Table Of Contents
- Spiskåpa 772–10/B
- SV Bruksanvisning
- Säkerhetsföreskrifter
- Installation
- Injustering av luftflöden
- Användning
- Service och garanti
- Emhætte 772–10/B
- DA Betjeningsvejledning
- Cooker hood 772-10/B
- GB User instructions
- Safety Instructions
- Installation
- Adjusting air flow
- Instructions for use
- Service and warranty
- Kjøkkenhette 772–10/B
- NO Bruksanvisning
- Fig. 15
- Fig. 16
- Fig. 17
- Fig. 18
Assembly
Adjusting frame height
Fig. 4
Adjust frame height to ceiling height and
cooker hood installation height. Measure
the total ceiling height. Deduct cooker
height, installation height and the chassis
dimensions; see dimensions drawing Fig. 1
.
Frame measurement = Total ceiling
height - cooker height - installation
height - chassis height.
When adjusting the height of the frame, re-
move the screws, (8 pcs) Fig. 4A. Adjust
the height of the frame and lock it by
screwing in the screws again. It may be ne-
cessary to move the screws to other hole
positions.
Adjusting the length of the hose/duct
for connection to the outlet air duct
Fig. 4B
Measured the frame's adjusted length. De-
duct the connection box dimensions; see
measurements drawing, Fig. 1.
Length of hose/duct = Frame measure-
ment - 235 mm.
Installing chimney drums
Fig. 5
Place the adjusted frame on the floor or on
a table that is protected with a piece of
cardboard from the packaging.
Slide the two drums onto the frame.
Fasten the outer drum to the frame using
screws E, Fig. 5A.
Ceiling installation
Lift up the frame and slot the key holes
over the four screws D Fig. 5, installed in
the ceiling/extension section.
Position the frame and tighten the screws.
Lock in place using the fifth screw, H Fig. 5.
Attention!
Turn the frame so that the arrow is on
the same side as the front of the cooker
hood.
Frame installation
Remove fat filter Fig. 14.
Adapt the length of the connection hose/
duct according to frame height, the ceiling
connection and the height of the connec-
tion box (235 mm).
Fit the connection hose/duct to the cooker
hood's outlet air collar.
24
991.0433.864/126183/2016-02-08