Installation , Operation and Maintenance Instructions Genius

6.4.2 Assembly
" Follow the assembly steps at the installation place in reverse order of disassembly.
6.5 Connections
6.5.1 Hydraulic Connections Storage Tank
All connections are lead through the rear side of the combi unit (ready-to-connect). The used electronic controlled high efciency pump
provides charging of the storage tank on demand.
Remove panels
The rear and right side panel are xed to the unit and can not be removed.
WARNING
Risk of impact or crushing due to falling parts!
The panels are not xed. They can fall down after loosening the screws.
» Hold the panels during loosening and put it down to the oor.
" Loosen the front and the side panel to install the unit.
" Hold the panels tight and remove them.
Figure 5: Hydraulic connections
1 150 litres drinking water tank 3 Heating safety valve 3 bar
2 6 litres expansion tank 4 Heating rod 3 kW, single phase
5 High efciency pump
6 Fill and drain valve with ½“ hose connection
NOTE
Ensure a professional noise reduction of the domestic water installation.
20
Assembly
Genius - V 1.0