Residential ventilation You make dreams a reality. We provide the efficient Air-Conditioning. Genius – the intelligent central building services unit for heating, cooling, ventilation and water heating.
A breath of fresh air: Genius by Systemair.
Every day you work passionately in bringing your dream homes to reality with your customers. We at Systemair share in this philosophy with intelligent technology operating energy efficiently perfectly adapted to the requirements of modern construction in all kinds of applications. Our “Genius” Central Building services unit has been developed accordingly. At last - 1 unit that can do everything from Heating, Cooling, Ventilation and Domestic Hot Water! Discover these fresh ideas for your customers.
Key Outdoor air Supply air Secondary air Extract air Exhaust air Where Oil, Gas and water once came – we now do it all with Air. Air heating system from Systemair Nowadays, whoever builds a new building or renovates an old one must fulfil the European Directive Energy Performance of Buildings (EPBD). The result is often highly insulated, airtight building envelopes which require mechanical residential ventilation – for a healthy indoor climate and as little energy loss as possible.
Genius is the compact Central Building Services Unit which can do everything: ventilation, heating, cooling and hot water production. All Genius needs is a secondary air circuit in addition to the conventional ventilation ducts. Thanks to the integrated air/ air heat pump, a heating system using water becomes unnecessary. How the air heating system works At the heart of the system is the Genius combi-unit.
One for all. All with air. Genius – the modern central building services unit Genius from Systemair is the intelligent solution for detached energy-efficient houses. Saving space, it combines controlled residential ventilation including heat recovery (up to 85%) with heating / cooling and hot water production. In combination with a photovoltaic system, it is even possible to realise a virtually selfsufficient and CO2 neutral system.
systemair 7
Increased comfort, decreased space requirement KEY Genius Hot water tank Boiler Air handling unit Underfloor heating Conventional system Genius air heating system Good to know The individual Genius components for ventilation, the heat pump and hot water are installed in compact modules, which can simply be pushed into the housing or placed on top. This makes installation and maintenance easier.
An overview of all the advantages of Genius: · In general, no additional heating is necessary – not even on very cold days · Heat recovery up to 85% · Project engineering by Systemair · Integrated150 litre drinking water storage tank · Reversible heat pump · Humidity recovery via rotary heat exchanger · Low space requirement · Contemporary, dimensioned for the requirements of energy-efficient houses · Control system optimises consumption · Easy to operate: via display, app, Internet, cloud · Advanced
Outdoor air Secondary air Extract air Supply air Ventilation module · Rotary heat exchanger with humidity recovery · Heating and cooling of the building via the ventilation system's supply air ducts. Heat pump module Exhaust air Outdoor air Hot water module Incl.
Comfortable in all areas. Modules, control, functions Modern technology requires contemporary, convenient operation. This is why we have designed Genius so that you and your customers can control the system easily with a PC and even via the Internet: as an expert via the service level and as an end user via the user level. This enables you and your customers to have permanent access, even from outside, and an optimum overview of all functions and parameters.
Thoroughly thought through. Genius in operation Ventilation mode Secondary air FS (ETS) SS Bathroom WC PTC RS Kitchen Living room Heat recovery unit SF (EHS) EF RF R1 PTC RS R2 PTC RS R3 PTC Heat pump Outside Living area RS RS R5 R1 B3 PTC PTC RS R6 Sleeping area The extract air is extracted via the kitchen, bathroom and WC. On its way to the outside, it flows over the rotary heat exchanger.
Hot water production without heating or cooling demand Secondary air FS (ETS) The ventilation functions as described in "Ventilation mode". If there is a demand for hot water, the compressor and the storage charging pump start. The residual energy of the extract air is used as in the heating mode. A plate heat exchanger is used. The hot gas of the refrigeration circuit flows through the primary side and hot water flows through the secondary side.
Exceptional in every discipline. The technical data Technical data Connections Electrical data Cold water 1" AG Voltage Hot water 1" AG Frequency Hz 50 1" AG Max. compressor power consumption W 1800 Max. fan power consumption Ventilation module W je 80 Max.
Air flow/pressure diagram 350 qv2 qv1 V2 300 V3 250 200 150 100 qVd V1 qVmin 50 0 0 qVref 50 100 150 200 250 300 350 400 Air flow [m3/h] Products you can rely on Distinct design, concentrated power Despite its many functions, Genius doesn't take up much space. What's more, the appealing design of the unit means it doesn't need to be hidden away in a special service room. 82 2 Quality: Systemair is certified according to ISO 9001, ISO 14001 and ATEX.
A well-coordinated team. The components The Systemair ventilation system consists of multiple components which are attuned to each other. At the centre of the entire system is the Genius Central Building Services Unit. A duct system distributes the air – consisting of corrugated spiral seam piping or plastic piping with round or oval cross-sections, depending on the requirements. There is an additional air duct system from the living area to Genius for the secondary air.
Something you can build on. Your comfort package from Systemair With Genius from Systemair, you are getting a topclass central building services unit. In the development of our products we place the highest value on quality, functionality, efficiency and reduced energy consumption. We only use top-quality components from renowned manufacturers. And because we really only want to deliver the best to you and your customers, we will test our new products thoroughly in advance. You can depend on that.
Sven Haustein, haalplatz architekten, Schwäbisch Hall, Germany „For years now we have been planning high-quality, airtight houses. They are very well-insulated with the best components and very low energy consumption. But due to the lack of alternatives for building services, until now we have always had to use expensive elements which were mostly over-dimensioned for the specific requirements, or were to a certain extent unnecessary. The Genius combi-unit is exactly the alternative that we needed.
Often asked. Happily answered. Our customers' FAQs What is the difference between secondary air and recirculating air? Recirculating air is extract air which is treated and then fed back as a component of the supply air to at least one room from which it was not originally taken. This means it is possible for odours and substances to be transmitted. In contrast, secondary air is removed from a supply air zone, fed through a separate duct system and, after treatment, is fed back into the same room.
www.systemair.