Installation, Operation and Maintenance instruction MUB Multibox fan AC/EC MUB-CAV/VAV Multibox fan EC MUB/T Thermo multibox fan AC/EC MUB/T ECO Thermo multibox fan AC/EC MUB/T-S Thermo multibox fan AC/EC MUB/F Smoke extract fan AC MUB+Filter Multibox fan AC EN
Table of content 1 Introduction .......................................................... 1 1.1 Product description ...................................... 1 1.2 Intended use .............................................. 1 1.3 Document description................................... 1 1.4 Product overview......................................... 2 1.4.1 Product overview MUB/T fans and MUB/T-S fans ................................. 2 1.4.2 Product overview MUB fans, MUB-CAV/VAV fans, and MUB/F fans ........
20 UKCADeclaration of Conformity-Thermo fans ................................................................. 41 21 UKCA Declaration of Conformity-Smoke extract fans .................................................................
1 Introduction 1.1 Product description The product is not supplied with an external speed controller or installation equipment, these parts are available as accessories. The MUB fan is a square multibox fan supplied with an EC or an AC motor, and modular panels for optional air discharge. 1.2 The MUB-CAV/VAV fan is a square multibox fan supplied with an EC motor, have modular panels for optional air discharge and an integrated pressure controller device for constant air volume control (CAV).
1.4 1.4.1 Product overview Product overview MUB/T fans and MUB/T-S fans 5 6 1 7 8 2 9 3 1. 2. 3. 4. 5. 2 Casing Motor (inside casing on MUB/T fans and MUB/T ECO fans) Motor connection box Fan impeller Name plate 6. 7. 8. 9.
1.4.2 Product overview MUB fans, MUB-CAV/VAV fans, and MUB/F fans 2 1 3 4 5 6 7 1. Casing 2. Fan impeller 3. Name plate 4. Airflow direction arrow 5. Pressure controller (only on MUB-CAV/VAV) 6. Motor 7. Motor connection box (only on MUB and MUB/F) 1. Type designation: Product name, dimension and motor type. Refer to 1.5.1 Type designation page 4. 2. Current, A 3. Input power, W 7 4. Frequency, Hz 8 5. Certifications 6. Scannable code 1 7. Voltage, V 8.
1.5.
1.6 Product liability 2 Safety Systemair is not liable for damages that the product causes in these conditions: 2.1 Safety definitions • The product is incorrectly installed, operated or maintained. Warnings, cautions and notes are used to point out specially important parts of the manual. • The product is repaired with parts that are not original spare parts from Systemair. Warning • The product is used together with accessories that are not original accessories from Systemair.
2.2 Safety instructions Warning Read the warning instructions that follow before you do work on the product. • Read this manual and make sure that you understand the instructions before you do work on the product. • Obey local conditions and laws. • The ventilation contractor and the operator are responsible for correct installation and intended use. • Keep this manual at the location of the product. • Do not install or operate the product if it is defective. • Do not remove or disconnect safety devices.
4 Installation 4.1 To do before the installation of the product 1 Remove the 4 screws that attach the side panel to the frame and remove the side panel. The picture shows the MUB/T fan which has the locking system for the panel shown. The MUB fans, the MUB/T fans, the MUB ECO fans and MUB/F fans have no locking system or handle, only screws in the frame. • Make sure that you have the necessary installation accessories: – Refer to 13 Accessory overview page 33 for an overview of the accessories.
4 If necessary, install cable grommets. Refer to 4.2.3 To install cable grommets page 8. Note: 5 The MUB fan, the MUB CAV/VAV fan and the MUB/F fan can be installed in any angle on the floor, on the wall or in the ceiling. If the product is a MUB-CAV/VAV fan, set up the CAV controller. Refer to 4.2.5 To set up the controller for CAV/ VAV page 9. 6 If the product is installed outside, install weather protection.
4.2.5 To set up the controller for CAV/VAV To install the weather protection roof (WSD) 1 The fan is delivered with an EC motor and an air flow controller device which is factory set for maximum airflow in CAV (constant air volume control) mode. The CAV controller measures the air volume and adjusts the 0-10 V output signal for the EC motor to keep the air volume constant.
4.2.7 To connect the ducts to the product 5 Warning To install the product with circular duct systems, Systemair recommends to use CCM or CCMI flanged plate. The MUB/F fan switches off in case of fire. The MUB/F fan has no motor protection fitted as standard. Any kind of motor protection and frequency converter must be bypassed in case of fire. To install the product in rectangular duct systems, Systemair recommends to use the flexible connection FGV.
5.4 To install motor protection for AC motors 6 Commissioning Caution • If the product has an built in motor protection, reset by disconnecting the product from power for 60 seconds. • If strong vibrations occur during commissioning, immediately increase or decrease the fan speed until the vibrations are decreased. Continuous strong vibrations can cause damage to components.
7 Operation Caution EC motors must be set to ON/OFF via the control input. To stop the product via mains supply decreases the life time of the motor. Systemair recommends to install external speed controller for easy access to control the input signal. 7.1 To start a product with an EC motor 1 Make sure that the 0–10 V signal is set to “0” with the speed controller. 2 Set the installed safety switch in the ON position and wait 5 seconds.
8 Maintenance Warning Set the installed safety switch in the OFF position before you do the maintenance unless the instructions tell you differently. Make sure that the safety switch is not accidentally set in the ON position. 8.1 Maintenance schedule The intervals are calculated from continuous operation of the product. Maintenance task Usual operation conditions Each 6 months Each year Unusual operation conditions.
9 Troubleshooting Note: If you cannot find a solution to your problem in this section, speak to Systemair technical support. Problem Cause Solution The fan impeller is not correctly balanced. Speak to Systemair technical support. There is dirt on the fan impeller. Clean the fan impeller carefully. Refer to 8.2 To clean the product page 13. The fan impeller has damages or deformations because the transported air contains aggressive media. Speak to Systemair technical support.
Problem Cause Solution The fan impeller does not turn in the correct direction. Make sure that the electrical connection is correctly done. A phase loss occurred. If the motor is a 3-phase motor, make sure that no phase is missing. Note: This is not applicable for EC motors. The motor is overheated. Thermal contacts, PTC or resistors are released. • Do a check of the motor cooling impeller. • If it is possible, measure the resistance to do a check of the motor winding.
10 Disposal The product follows the WEEE directive. This symbol on the product or the packaging of the product shows that this product is not domestic waste. The product must be recycled at an approved disposal location for electrical and electronic equipment. 11 Warranty For warranty claims, send a written maintenance plan and the commissioning report to Systemair. The warranty is only applicable for these conditions: • The product is correctly installed and operated. • Motor protection is used.
12 Technical data 12.1 Technical data overview Max. temperature of transported air, °C Max. ambient temperature, °C Refer to the data sheet in the online catalogue at www.systemair.com. Sound pressure, dB IP class Voltage, current, frequency, enclosure class, weight Refer to the name plate. Refer to 1.5 Name plate page 3 for more information. Motor data 12.2 Refer to the motor name plate or the technical documentation from the motor manufacturer. Product dimensions 12.2.
C D E B A A B C D E MUB 025 315/355 21 520 378 420 520 MUB 042 400/450/500 21 690 548 590 690 MUB 062 560/630 21 820 678 720 820 MUB 100 630/710 21 1020 878 920 1020 12.2.2 Product dimensions MUB-CAV/VAV fans Note: If the unit of measure is not specified, the dimensions are given in millimetres.
A B C D E F MUB-CAV/VAV 062 560/630 820 720 678 820 21 906 MUB-CAV/VAV 100 630/710 1020 920 878 1020 21 1106 12.2.3 Product dimensions MUB/T fans Note: If the unit of measure is not specified, the dimensions are given in millimetres.
12.2.4 Product dimensions MUB/F fans Note: If the unit of measure is not specified, the dimensions are given in millimetres.
12.2.5 Product dimensions MUB/T-S fans Note: If the unit of measure is not specified, the dimensions are given in millimetres.
A B C D E F G MUB/T-S 062 500 D4 820 678 720 820 1034 1” (inch) 21 MUB/T-S 062 560 D4 820 678 720 820 1070 1” (inch) 21 MUB/T-S 062 500 EC 820 678 720 820 1012 1” (inch) 21 MUB/T-S 062 560 EC 820 678 720 820 1050 1” (inch) 21 MUB/T-S 100 630 D4 1020 878 920 1020 1201 1” (inch) 21 12.2.6 Product dimensions MUB/T ECO fans Note: If the unit of measure is not specified, the dimensions are given in millimetres.
12.2.7 Product dimensions MUB+Filter fans Note: If the unit of measure is not specified, the dimensions are given in millimetres. A B C D A B C D MUB + Filter 025 315/355 690 378 520 71 MUB + Filter 042 400/450/500 820 548 690 71 MUB + Filter 062 560/630 1020 678 820 71 MUB + Filter 100 630 1020 878 1020 71 12.3 Wiring diagrams 12.3.1 Wiring diagrams for AC fans Refer to the wiring diagram documents that are included in the supply of the product.
12.3.3 Wiring diagrams for speed controller for AC motors Note: The selection of electrical accessories must be done in line with the technical parameters of the product. RE Manual 5-step transformer. RE 1,5 ~ RE 3 N RE 5 RE 7 ~ N A N B C D A. Relay connection. There is always 230 V between ~ and N when the transformer knob is in one of the positions 1–5. B. Mains supply C. Earth D. Fan REE — Thyristor REE 1 and REE 2 - Surface mounting or with flush mounting casing included.
RTRE Manual 5-step transformer with motor protection. RTRE 1,5 RTRE 3 ~ ~ N RTRE 5 N N B C Rt D Rt Tk Tk E F A RTRE 7 RTRE 12 ~ N ~ N A N B C Rt D Rt Tk Tk E F A. Relay connection. There is always 230 V between ~ and N when the transformer knob is in one of the positions 1–5. B. Mains supply C. Earth D. Fan E. Thermostat F. Motor protection. If the motor protection is not in use, Tk must be looped together.
A. Contact rating, maximum AC 250 V/2 A B. Mains supply, 1–phase 208...277 V, 50/60 Hz C. Motor with internal thermal contacts D. OFF/ON RTRD A 3-phase transformer that controls the fan speed by altering the supply voltage in five fixed steps. The steps are adjusted by using the control knob on the front of the unit. RTRD2-7 N L L RT RT FS FS TK TK A A B N L1 L2 L3 N L1 L2 L3 U V W A 230 V AC PE U W M 3~ E 01 V TB TB C A.
RTRDU Manual 5–step transformer with motor protection — a 3–phase transformer that controls the fan speed by altering the supply voltage in five fixed steps. The steps are adjusted by using the control knob on the front of the unit. RTRDU A 0 B 0 5 15 4 24 3 1 1 2 3 2 3 N L L RT RT FS FS TB TB A A N L1 L2 L3 PE N L1 L2 L3 U V W A 230 V AC max. 1 A 230 V AC U F B 01 TB TB C D E A. If the function is not necessary, the terminals must be bridged B.
MTP 20 MTP 20 1/Vdc+ +10V 4/Vout 0...10V 2/Vdc- GND 3/Vout- EC-Basic EC-Basic 1/IN Vac 230V AC 2/IN Vac +10V 4/Out 0...10V 5/GND GND MTV–1/10 MTV 1/010 1/IN Vac 230V AC 2/IN Vac +10V 4/Out+ 0...10V 5/Out- GND S-5EC/FRQ MTP 10 10V +10V GND 0...10V A GND EC-Vent EC-Vent IN/RPM optional IN/10V OUT/PWN GND 28 TACH +10V PWM 0...
12.3.5 Wiring diagrams for ON/OFF controls for EC motors CO2RT-R(-D) CO2RT-R-D Supply +10V Neutral 0...10V Common GND 24V AC Relay NO Relay NC Din1 IR24–P IR24-P 24V +10V Neutral 0...10V Common GND 24V AC or DC Relay NO Relay NC 12.3.6 Din1 Wiring diagrams for demand control for EC motors EC Basic EC Basic-T for temperature control EC Basic-CO2/T for temperature and CO2 control EC Basic-H for humidity control EC-Basic 1/IN Vac 230V AC 2/IN Vac +10V 4/Out 0...
EC-Vent Demand control for up to 5 external sensors, 2 fans, dampers, heaters and coolers. The EC vent system has 2 units. The control board (CB) and the room unit (RU). Connect the fan to the control board and remove the internal potentiometer. EC-Vent IN/RPM optional TACH IN/10V OUT/PWN +10V PWM 0...
Control Board (CB) I 5 (GND) 6 (0-10V) 7 G + DC MAX 24V I max 50mA H 2 (+24VDC) 3 (0-10V) 1 (GND) 1 (tach output) 2 (GND) 3 (PWM) 4 (+10VDC) N L F OUT3 OUT2 24V D A GND ALARM FAN 24V D A GND E OUT1 IN2 C B IN2 WY +0-10V Br + 24VDC GND A/D PT1000 24V GND A/D PT1000 24V GND A/D PT1000 24V DEBUG J K USB 24V D A GND MODBUS INTERNAL IN3 NC C NO GND +24VDC GND IN/10V OUT/PWM IN/RPM CMN NC NO D RU N out N in L out L in A A. Mains supply, 230 V 1~AC (10 A) B.
MM6-24/D output signal selector Compares signals from connected inputs and transfers the signal to the control output. 1 Input 1 0...10 V 2 Input 2 0...10 V 3 Input 3 0...10 V 4 Input 4 0...10 V 5 Input 5 0...10 V 6 Input 6 0...10 V 7 System neutral 8 24 V AC 9 Signal neutral 10 Signal neutral 11 Output minimum 0...10V 12 Output maximum 0...10V Mains supply PCA 1000D2 Pressure controller PCA 1000/6000D2 R i = 4 kΩ p PI V 1(+) 2( ) +US GND A GND + ∆p - + US 3 1 01 10...
13 Accessory overview 13.1 Accessory overview MUB fans, MUB-CAV/VAV fans, MUB/T fans, MUB/T-S,MUB/T ECO and MUB+Filter fans Note: For more information about accessories, refer to www.systemair.com or speak to Systemair technical support. 3 1 7 4 5 8 1 9 2 3 6 4 1. 2. 3. 4. 5. FGV: Flexible connection WSG: Weather protection grille UGS: Transition connections, square to round Tune-AHU: Damper CCM inlet: Flanged plate for air handling units 6. 7. 8. 9.
13.2 Accessory overview MUB/F fans Note: For more information about accessories, refer to www.systemair.com or speak to Systemair technical support. 1 5 2 3 4 1. 2. 3. 34 RSA: Silencer EVH: Flexible connection LRK: Air-operated damper 4. 5.
14 EU Declaration of Conformity-Multibox We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Multibox Type/Model MUB 025 315–710; MUB 016 200–710EC; MUB-CAV/VAV 025 315–710EC Identification Serial numbers dating from 2022 and onwards fulfils all relevant provisions of the Machinery directive 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General principles for design Riska
15 EU Declaration of Conformity-Multibox+Filter We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Multibox+Filter Type/Model MUB+Filter, MUB+Filter EC Identification Serial numbers dating from 2021 and onwards fulfils all relevant provisions of the Machinery directive 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General principles for design Riskassessment and risk red
16 EU Declaration of Conformity-Thermo fans We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Thermo fans Type/Model AxZent; KBR; MUB/T; MUB/T-S; DVN; DVNI Identification Serial numbers dating from 2022 and onwards fulfils all relevant provisions of the Machinery directive 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General principles for design Riskassessment and ris
17 EU Declaration of Conformity-Smoke extract fans We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Smoke extract fans Type/Model KBR/F; MUB/F Identification Serial numbers dating from 2022 and onwards fulfils all relevant provisions of the Machinery directive 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General principles for design Riskassessment and risk reduction
18 UKCA Declaration of Conformity-Multibox We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Multibox Type/Model MUB 025 315–710; MUB 016 200–710EC; MUB-CAV/VAV 025 315–710EC Identification Serial numbers dating from 2022 and onwards fulfils all relevant provisions of the Supply of Machinery (Safety) Regulations 2008 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General
19 UKCA Declaration of Conformity-MUB+Filter We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Multibox+Filter Type/Model MUB+Filter 025–062 315–630, MUB+Filter 025–062 355–630EC Identification Serial numbers dating from 2021 and onwards fulfils all relevant provisions of the Supply of Machinery (Safety) Regulations 2008 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - Gen
20 UKCADeclaration of Conformity-Thermo fans We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Thermo fans Type/Model AxZent; KBR; MUB/T; MUB/T-S; DVN; DVNI Identification Serial numbers dating from 2022 and onwards fulfils all relevant provisions of the Supply of Machinery (Safety) Regulations 2008 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General principles for de
21 UKCA Declaration of Conformity-Smoke extract fans We, the manufacturer Company Systemair GmbH Address Seehöfer Straße 45 97944 Boxberg Germany declare under our sole responsibility that the product Product designation Smoke extract fans Type/Model KBR/F; MUB/F Identification Serial numbers dating from 2022 and onwards fulfils all relevant provisions of the Supply of Machinery (Safety) Regulations 2008 2006/42/EC DIN EN ISO 12100:2013 Safety of machinery - General principles for design Riskas
43
last page Systemair GmbH Seehöfer Str. 45 97944 Boxberg Germany Tel.: +49 (0)7930/9272-0 Fax: +49 (0)7930/9273-92 info@systemair.de www.systemair.de © Copyright Systemair AB All rights reserved EOE Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications.