DoP DVV F600

OSK 03-13-R0_I067AA_04_DVV_F600_DoP_09_08_2021.docx
Declaration of Perfomance
No.: I067AA.04-DVV-F600-DoP
1. Unique identification code of the product-type
DVV, DVVI (with silencer HSDV) -XS, XM, XL, XP/F600
2. Type, batch or serial number or any other element allowing identification
of the construction product
DVV size/D motor pole(s)-impeller type/temperature-time
class
3. Intended use of the construction product
Powered smoke and heat exhaust ventilator for use in
construction works
4. Name and contact address of the manufacturer
Systemair d.o.o. Špelina ulica 2, 2000 Maribor, Slovenia
5. System of assessment and verification of constancy of performance of
the construction product
System 1
6. In case of the declaration of performance concerning a construction
product covered by a harmonized standard
EN 12101-3:2015
Name and identification number of the notified bodies
BSI Group The Netherlands B.V., id. number: 2797
Description of tasks, performed by the notified bodies
Determination of the product type on the basis of type
testing (including sampling), type calculation, tabulated
values or descriptive documentation of the product;
initial inspection of the manufacturing plant and of factory
production control;
continuous surveillance, assessment and evaluation of
factory production control.
EC Certificate of conformity, issued by the notified bodies
2797-CPR-597958
Essential
characteristics
Performance/Reference
Harmonized
technical
specification
Temperature/
time
classification
F600
a)
Test reports No. P 0959/14-530-1, No. P 0046/15-
530-1, Range report No. P 0046/15-530-2, issued by
the ZAG, Ljubljana, Slovenia
a)
minimum functioning period at tests 120 min
EN 12101-3:2015,
Smoke and heat
control systems-
Part 3: Specification
for powered smoke
and heat control
ventilators (Fans)
Wind load
NPD
<30s/200Pa, if fitted with FSL
accessories
Test report No. 3510, issued by Forschungslabor für
Haustechnik der Technischen Universität München
Snow load
SL 0
Test report No. 3510, issued by Forschungslabor für
Haustechnik der Technischen Universität München;
EC Certificate 2797-CPR-597958
SL 1000, if fitted with FSL accessories
Application
classes
For use outside building
Range report No. P 0046/15-530-2, issued by the
ZAG, Ljubljana, Slovenia
Only for use on a rooftop
Applicable for vertical drive shaft
position
Dual purpose
SL 0 may be suitable on top of heated
buildings
SL 1000 (fitted with FSL accessories)
applicable for non-heated buildings up
to SL 1000
EC Certificate 2797-CPR-597958
Tested
accessories
Flexible connection ASSG/F
Test report BB-TUM 011-2004, issued by
Forschungslabor für Haustechnik der Technischen
Universität München
Roof base with silencer SSGE/F, SSG/F
roof base FDGE/F, inflow box ASG/F
Air operated flap VKG/F
Range report No. P 0046/15-530-2
, issued by the
ZAG, Ljubljana, Slovenia
Roof base FDG/F
Snow load flap FSL
Test report No. 3510, issued by Forschungslabor
für Haustechnik der Technischen Universität
München;
EC Certificate 2797-CPR-597958
Outlet silencer HSDV
Frequency converter without sine filter
(tested with DVV)
Range report No. P 0046/15-530-2
, issued by the
ZAG, Ljubljana, Slovenia
Signed for and on behalf of the manufacturer by:
Maribor, 08.09.2021 Anton Zupančič, Director